Leveling Machine
This jointer should be positioned on level, stable floor. If machine is rocking on the floor, or if it vibrates
excessively during operation, please adjust the rubber feet to level the machine:
1.
Loosen the jam nut to unlock leveling foot.
2.
Rotating the leveling foot to adjust its height.
3.
Make adjustments on all other leveling feet until machine is
completely leveled.
4.
Tighten jam nuts of all adjusted leveling feet.
Dust Collection
Jointer can generate a lot of wood shavings and dusts. Connect dust
collection system to this machine.
Minimum CFM requirement for this jointer is 700 CFM at the dust port,
which means your dust collection system should have a rating greater than
700 CFM, as air friction from the ducts reduces effective CFM at dust ports.
IMPORTANT
Running this jointer without dust collection system, or using a dust collection
system with inadequate suction, will cause dust and shavings to accumulate
inside the jointer. This can damage the machine and cause other hazardous
situations. Check your dust collection system regularly to make sure it is not
jammed or filled up.
Summary of Contents for 4265
Page 2: ......
Page 10: ...10 Page Oliver Machinery 4265 Jointer Identification...
Page 11: ...4265 Jointer OLIVERMACHINERY NET 11 Page...
Page 51: ...4265 Jointer OLIVERMACHINERY NET 51 Page Wiring Diagram For Stock 4265 101 4S 230V 1Ph...
Page 52: ...52 Page Oliver Machinery 4265 Jointer For Stock 4265 102 4S 230 460V 3Ph...
Page 53: ...4265 Jointer OLIVERMACHINERY NET 53 Page Parts List Fence Assembly...
Page 54: ...54 Page Oliver Machinery 4265 Jointer Table and Cutterhead Assembly...
Page 55: ...4265 Jointer OLIVERMACHINERY NET 55 Page Base Assembly...
Page 56: ...56 Page Oliver Machinery 4265 Jointer Motor and Cabinet...
Page 66: ...66 Page Oliver Machinery 4265 Jointer Maintenance Record Date Task Operator...
Page 67: ...4265 Jointer OLIVERMACHINERY NET 67 Page Notes...