11) VCOM LUT (LUTC) (R20H)
This command stores VCOM Look-Up Table with 10 groups of data. Each group contains
information for one state and is stored with 6 bytes (byte 2~7, 8~13, 14~19, 20~25,
…
), while the
sixth byte indicates how many times that phase will repeat.
Bytes 2, 8, 14, 20, 26, 32, 38, 44, 50, 56:
D[7:6], D[5:4], D[3:2], D[1:0]: Level Selection
00b: VCOM_DC
01b: VDH+VCOM_DC (VCOMH)
10b: VDL+VCOM_DC (VCOML)
11b: Floating
Bytes 3~6, 9~12, 15~18, 21~24, 27~30, 33~36, 39~42, 45~48, 51~54, 57~60:
Number of Frames
0000 0000b: 0 frame
:
:
:
:
1111 1111b: 255 frames
Bytes 7, 13, 19, 25, 31, 37, 43, 49, 55, 61:
Times to Repeat
0000 0000b: 0 time
:
:
:
:
1111 1111b: 255 times
If KW/R=0 (KWR mode), all 10 groups are used.
If KW/R=1 (KW mode), only 7 groups are used.
EPD Module User Manual
2.5$7HFKQRORJLHV
5HY
20
/