12.
Inspection condition
12.1 Environment
Temperature
:
23±3
℃
Humidity
:
55±10%RH
12.2 Illuminance
Brightness:1200
~
1500LUX;distance: 20-30CM;Angle:Relate 45°surround.
12.3 Inspect method
12.4 Display area
12.5
Ghosting
test
method
Three-color
ghosting
is
measured
with
following
transition
from
horizontal
3
scale
pattern
to
vertical
3
scale
pattern.
The
listed
optical
characteristics
are
only
guaranteed
under
the
controller
&
waveform
provided
by
OKRA
.
1
)
Measurement Instruments
:
X-rite i1Pro
2
)
Ghosting formula:
W ghosting
:△
E= Max (
Δ
Eab(W-W, R-W),
Δ
Eab(W-W, B-W),
Δ
Eab(B-W, R-W))
K ghosting
:△
E= Max (
Δ
Eab(B-B, W-B),
Δ
Eab(B-B, R-B),
Δ
Eab(R-B, W-B))
R ghosting
:△
E= Max (
Δ
Eab(R-R, W-R),
Δ
Eab(R-R, B-R),
Δ
Eab(B-R, W-R))
20min
30min
20min
EPD Module User Manual
2.5$7HFKQRORJLHV
5HY
36
/
41