2) POWER SETTING (PWR) (R01H)
BD_EN:
Border LDO enable
0 : Border LDO disable (Default)
Border level selection: 00b: VCOM
01b: VDH 10b: VDL 11b: VDHR
1 : Border LDO enable
Border level selection: 00b: VCOM 01b: VBH(VCOM-VDL) 10b:VBL(VCOM-VDH)
11b: VDHR
VSR_EN:
Source LV power selection
0 : External source power from VDHR pins
1 : Internal DC/DC function for generating VDHR. (Default)
VS_EN:
Source power selection
0 : External source power from VDH/VDL pins
1 : Internal DC/DC function for generating VDH/VDL. (Default)
VG_EN:
Gate power selection
0 : External gate power from VGH/VGL pins
1 : Internal DC/DC function for generating VGH/VGL. (Default)
VCOM_SLEW:
VCOM slew rate selection for voltage transition. The value is fixed at “1”.
VG_LVL[2:0]:
VGH / VGL Voltage Level selection.
EPD Module User Manual