Pellematic settings
81
27.11 FRT Controller
FRT Controller
is in the Pellematic menu.
FRT Controller
has following menu items.
• Mode
• Min Temp
• Set Value ++
• Limit Up
• Limit Down
• PID Controller Amplification
• PID Controller Time Integral
• PID Controller Time Differential
The additional menu items
FRT Controller
are for the ÖkoFEN Service technician. They are present after entering
the code:
Mode
The activation of the FRT Controller of the combustion chamber temperature is only
possible with a connected combustion chamber sensor.
On
… FRT Controller active
Off
… FRT Controller inactive
Min Temp
Is the combustion chamber temperature minimum for a successful ignition.
Set Value ++
Set Value ++
for the regulation of the combustion chamber temperature.
Limit Up
If the combustion chamber temperature falls below the
Set Value ++
, increases the
run time of the burner auger maximum of this percentage.
Limit Down
If the combustion chamber temperature raises above the
Set Value ++
, decreases
the run time of the burner auger maximum of this percentage.
PID Controller
Amplification
P-contingent for the regulation of the combustion chamber temperature.
PID Controller Time Integral
I-contingent for the regulation of the combustion chamber temperature.
PID Controller Time
Differential
D-contingent for the regulation of the combustion chamber temperature.
E1389EN 2.0