Technical Reference Guide – Interface specifications > 25
Signalling levels
NOTE
Signalling Levels
Bus State
Required
Acceptable
Differential “1”
(D+)-(D-)> 200mV and D+ > V
IH
(min)
(D+)-(D-)> 200mV
Differential “0”
(D-)-(D+)> 200mV and D- > V
IH
(min)
(D-)-(D+)> 200mV
Single-ended 0 (SE0)
D+ and D- < V
IL
(max)
D+ and D- < V
IH
(min)
Data J state:
Low-speed
Full-speed
Differential “0”
Differential “1”
Data K state:
Low-speed
Full-speed
Differential “1”
Differential “0”
Idle state:
Low-speed
Full-speed
D- > V
IHZ
(min) and D+ < V
IL
(max)
D+ > V
IHZ
(min) and D- < V
IL
(max)
D- > V
IHZ
(min) and D+ < V
IH
(min)
D+ > V
IHZ
(min) and D- < V
IH
(min)
Resume state
Data K state
Start-of-
Packet (SOP)
Data lines switch from Idle to K state
End-of-Packet (EOP)
SE0 for
≥
1 bit time
1
followed by a J
state for 1 bit time
SE0 for
≥
1 bit time
1
followed by a J
state
Disconnect
(at downstream port)
SE0 for
≥
2.5
μ
s
Connect
(at downstream port)
Idle for
≥
2ms
Idle for
≥
2.5
μ
s
Reset
D+ and D- < V
IL
(max) for
≥
10ms
D+ and D- < V
IL
(max) for
≥
2.5
μ
s
The width of EOP is defined in bit times relative to the device
type receiving the EOP. The bit time is approximate.
Summary of Contents for ML1120
Page 1: ...ML1120 ML1190 eco Technical Reference Guide...
Page 212: ...Technical Reference Guide Appendix C Code pages 212 APPENDIX C CODE PAGES ML1190 eco...
Page 213: ...Technical Reference Guide Appendix C Code pages 213...
Page 214: ...Technical Reference Guide Appendix C Code pages 214...
Page 215: ...Technical Reference Guide Appendix C Code pages 215...
Page 216: ...Technical Reference Guide Appendix C Code pages 216...
Page 217: ...Technical Reference Guide Appendix C Code pages 217...
Page 218: ...Technical Reference Guide Appendix C Code pages 218...
Page 219: ...Technical Reference Guide Appendix C Code pages 219...