Technical Reference Guide – Command descriptions > 120
DLL Data format is be sent in the following manner:
At loading time, if printer is in Super/Sub mode then only
two bytes of data are required for each column.
L
OAD
DLL
CHARACTER
>
Code: ESC = n1 n2 # a1 a2 a3 m ad1 ad2 id1 id2 d1 d2
d3 d4 d5 [data]
>
Compatibility:
ML1190 eco: IBM
ML1120 eco: IBM III
>
Function:
This sequence initiates character downloading.
>
Range:
n1 = 0 – 255, Number of bytes in command string.
n2 = 0 – 255, N1 + n2 × 256
a1 = 0 – 255, Data starting address.
a2 = 0 – 255
a3 = 0 – 255
d0 + d1 + d2 = cell matrix width
3
6
9
12
3m
b0~b7 valid as DLL Data
LSB
2
4
6
11
3m-1
b0~b7 valid as DLL Data
LSB
MSB
1
3
5
10
3m-2
b0~b7 valid as DLL Data
LSB
MSB
MSB
d0
d1
d2