FX
/RB
/RVE
Installation and connections
GB - 13
FIG. 5
2
2
3
4
6
5
5
1
1
3.4.a - Control of a correct electrical connection
(Fig. 5)
For the connection 230/400 V three phase, it is necessary
to check if the engine rotation is right, to do this proceed
as follows:
• The cutout switch placed at the machine upper side
shall be positioned on “ON”.
• Turn the timer knob (1) onto "
".
• Press the key (2) "
".
• Visually make sure the container (3) rotates according
to the direction indicated by the arrow (4).
Disconnect the machine by pressing "
" (5)
If the rotation direction is contrary to the arrow direction,
proceed as follows:
DANGER
Before making any change in the electrical
connection, make sure that the DISCONNECTING
SWITCH is disconnected (line not energized),
then:
reverse two of the three phase wires on the main
switch and check again the correct rotation.
3.4.b - Unipotential connection (Fig. 5)
The machine is provided with a screw (6) for unipotential
connection.
To make the connection, unscrew the screw nut (6),
connect the cable of the unipotential net to the screw
and tighten the nut again.
3.5 - FIRST START (Fig. 5)
• The cutout switch placed at the machine upper side
shall be positioned on “ON”.
• Turn the timer knob (1) onto "
".
• Press (2) "
".
• Let the machine idle for a few minutes and check if the
rotation is regular and free.
• Disconnect the machine by pressing "
" (5).