11.ELECTRICAL SYSTEM
11-1
11. ELECTRICAL SYSTEM
CHARGING SYSTEM ································· 11-1 RESISTAMCE OF GENERATOR COIL ············ 11-1
NO- LOAD PERFORMANCE OF THE GENERATOR
····························································· 11-1
REGULATOR/RECTIFIER ··························· 11-2
STARTING SYSTEM ·································· 11-2 STARTER MOTOR ····································· 11-2
BRUSH BRUSH ········································ 11-3 RECTIFIER ·············································· 11-3
ARMATURE COIL ····································· 11-3 OIL SEAL ················································ 11-3
STARTER RELAY ······································ 11-3 AUXILIARY STARTER RELAY ····················· 11-4
EFL SYSTEM ··········································· 11-4 LGNITION SYSTEM ·································· 11-5
LGNITION COIL ······································· 11-5 INDICATOR LIGHT ··································· 11-7
BATTERY ················································ 11-7 RELAY AND FUSE ···································· 11-9
LAMPS (LED) ·········································· 11-9 SWITCHES ············································ 11-10
CHARGING SYSTEM
RESISTAMCE OF GENERATOR COIL
Measure the resistance between three wires;
If the resistance is not within the specified value,
replace the stator coil.
Check the generator core whether it is insulated.
Install multimeter 1×10Ω.
Resistance of generator coil: 0.9-1.5Ω (color: white)
Insulation resistance ∞Ω (
white - grounding wire
)
NO- LOAD PERFORMANCE OF THE GENERATOR
Start the engine with the speed at 5000r/min.
Measure AC voltage three wires inside the generator
with the multimeter.
If the voltage drops below a specified value, replace
the generator.
Put the multi meter at AC step.
No- load performance of the generator:
﹥
100V (
AC) at
5000r/min