Q45 1.2
1.2 Diagnostic Mode Settings and Error Codes
The Q45/Q45e/Q45ce elliptical machine offers a diagnostics mode to test the console and brake functions. To
enter the diagnostics mode, hold down the Time +/- and Level +/- keys simultaneously for three (3) seconds. The
tests and results are displayed in the console windows (as shown in Figure 1.4, upper and lower keypads), as
indicated in the chart below. The first three tests (D1 through D3) run automatically. You must use the +/- keys to
navigate through the remaining diagnostic tests options, pressing Enter to select the test you want to perform.
The following diagnostics are available on the Q45/Q45e/Q45ce:
Description
Matrix
Window 1 Window 2 Window 3
Window 4
Check memory
D1
Brake motor test
RESISTANCE
TEST
D2
1-30
Check all keys
(You must press each
key and listen for the
beep to verify that it
works properly before
you can move on to the
next test).
D3
Check all LEDs (Machine
cycles through all LEDs
in all windows; when you
have verified all LEDs,
press any + key to move
to the next test.)
All LEDs light
up
All LEDs
light up
All LEDs
light up
All LEDs
light up
All LEDs
light up
Software version
Version #
Version #
Version #
Version #
Total distance of machine
TD
Distance
value
Total time of machine
usage
TT
Usage
hours
Total motor on time
MOT
Motor on
hours
When you first enter the diagnostic mode, three customization features are displayed which allow some default
settings to be changed. Press any + or - key to change a setting; press Enter to advance to the next feature.
Description
Matrix
Window 1
SmartStride RPM Delta: Allows you
to set the RPM delta. Range is 5 to
15 RPM.
SSRD
Value in RPM
(Default = 5)
Smart Stride Check Time: Allows
you to set the number of seconds
between RPM checks after the stride
motors stop moving. Range is 5 to
15 seconds.
SL
Value in Seconds
(Default = 5)
Warm-up on/off: Allows you to
de-activate the 3-minute warm-up
period for non-heart rate-controlled
programs (P2-P5 and P11-P15).
WUP
“On” or “Off”
(Default = ON)
To exit the diagnostics and customization mode and save your changes, press the Pause/Clear button twice
within 2 seconds.
Summary of Contents for Q45
Page 1: ...Q45 Q45e Q45ce ...
Page 2: ......
Page 4: ......
Page 5: ...Notes ...
Page 6: ...Figure 1 1 Figure 1 3 Right Clevis Notice step orientation to outside of machine Figure 1 2 ...
Page 8: ...Q45 1 2 Figure 1 4 ...
Page 12: ...Figure 2 2 Figure 2 3 Figure 2 1 Q45 2 1 ...
Page 14: ...Figure 2 5 Q45 2 2 Figure 2 6 ...
Page 16: ...Figure 2 7 Q45 2 2 Figure 2 8 Nylock nut Clevis bushing Figure 2 9 ...
Page 18: ...Q45 2 2 Figure 2 11 Figure 2 12 Figure 2 10 ...
Page 20: ...Q45 2 2 Figure 2 13 Figure 2 14 Figure 2 16 Figure 2 15 ...
Page 22: ...Q45 2 2 Figure 2 20 Figure 2 19 Figure 2 17 Figure 2 18 ...
Page 24: ...Figure 2 22 Q45 2 3 Figure 2 21 Speed Speed Sensors Sensors ...
Page 26: ...Q45 2 3 Figure 2 27 Figure 2 25 Figure 2 23 Figure 2 24 ...
Page 28: ...Figure 2 28 Figure 2 27 Figure 2 29 ...
Page 30: ...Figure 2 30 Figure 2 32 Figure 2 31 ...
Page 38: ...Q45 2 5 Figure 2 41 ...
Page 40: ...Q45 2 5 Figure 2 42 ...
Page 42: ...Q45 3 1 Figure 3 1 ...
Page 44: ...Q45 3 1 Notes ...
Page 46: ...Q45 3 2 Notes ...
Page 48: ...Figure 3 7 Q45 3 4 Figure 3 6 Stability Link 18mm Bolt ...
Page 54: ...Q45 3 6 Notes ...
Page 56: ...Q45 3 8 Figure 3 14 Figure 3 15 ...
Page 58: ...Figure 3 16 Figure 3 17 Figure 3 18 Q45 3 9 ...
Page 60: ...Q45 3 9 Notes ...
Page 62: ...Q45 3 11 Figure 3 21 Figure 3 20 Figure 3 22 Older units Newer units ...
Page 64: ...Q45 3 12 Figure 3 24 Figure 3 23 ...
Page 66: ...Figure 3 26 Figure 3 25 Speed Sensors Q45 3 13 ...
Page 68: ...Notes Q45 3 13 ...
Page 70: ...Q45 3 15 Figure 3 29 Figure 3 28 ...
Page 72: ...Q45 3 15 Notes ...
Page 74: ...Q45 3 17 Figure 3 31 Figure 3 32 Figure 3 33 ...
Page 76: ...Q45 3 18 Figure 3 34 Figure 3 35 Figure 3 36 ...
Page 78: ...Q45 3 19 Figure 3 37 Figure 3 38 ...
Page 80: ...Q45 3 20 Figure 3 39 Figure 3 41 Figure 3 40 ...
Page 82: ......