BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08.docx
Page 32 of 92
4.2.2 Main components
1
Magnesium anode
2
Air vent valve (MFA)
3
Electric booster heater 8.8 kW (MFA)
4
Safety valve (MFA)
5
3-way switching valve (MFA)
6
Electrical connection
7
Cable entries
8
Maintenance flange
9
Drain stopcock
10
Buffer tank (100 l)
11
Drain stopcock
12
Heating circuit pump
13
Buffer charging pump
14
DHW tank (168 l)
15
Condenser (plate heat exchanger)
16
High limit safety cut-out (MFA)
17
Air vent valve
Figure 34: Main components in T200 indoor unit
4.2.3 Installation
4.2.3.1 Installation location
CAUTION
Do not install the appliance in damp
rooms!
Install the appliance in a frost free and dry room
near the draw-off point. In order to reduce line
losses, keep the distance between appliance and
heat pump small.
Ensure that the floor has adequate load bearing
capacity and is sufficiently level (for weight, see
section "Specification / Data table"). The room
must not be endangered by explosive dust, gases
or vapours.
If installing the appliance in a boiler room with
other heating appliances, ensure that their
operation is not affected.
Minimum clearances:
Summary of Contents for AIR BASIC 109
Page 2: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 2 of 92...
Page 22: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 22 of 92...
Page 79: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 79 of 92...
Page 80: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 80 of 92...
Page 81: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 81 of 92...
Page 82: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 82 of 92 11 5 ERP Data...
Page 83: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 83 of 92...
Page 84: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 84 of 92...
Page 85: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 85 of 92...
Page 86: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 86 of 92...
Page 87: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 87 of 92...
Page 90: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 90 of 92...
Page 91: ...BA_AIR_BASIC_ELW_Multitower_OTE3_SW5x_CC_EN_V08 docx Page 91 of 92...