DESCRIPTION
UT-MT-0812_2.0_24-01-2023 (EN)
Use and Maintenance Manual
LERA
14
2.8 A
6.6 A
Without Arctic Kit
0.96
0.98
With Arctic Kit
0.98
0.98
2.8
Mounting system
Always respect the project quotas. Before proceeding with the installation and commissioning
of the device, check the position and ground and elevation.
All fixtures installed on the pole (C configuration) are supplied without pole and without any frangible coupling.
Installation elements must be ordered separately.
The aluminium pole (Ø 60 mm) is available in standard length versions from 0.15 to 2.0 m. The pole can be cut to
size according to the installation project.
Code
Description
Features
315.3710
Support pole 150 mm
Support pole Ø 60 mm H = 150 mm
315.3711
Support pole 500 mm
Support pole Ø 60 mm H = 500 mm
315.3712
Support pole 1000 mm
Support pole Ø 60 mm H = 1000 mm
315.3713
Support pole 1500 mm
Support pole Ø 60 mm H = 1500 mm
315.3714
Support pole 2000 mm
Support pole Ø 60 mm H = 2000 mm
155.7200
Frangible coupling
Frangible coupling for pole Ø 60 mm (LERA configuration C-050/C-250)
2.7
Wiring
The LERA fixture can be connected through connectors FAA L-823 style 5/6 to an isolation transformer in series
FAA L-830/L831 (60/50 Hz).
The consumption varies depending on the number of light sources installed and on the presence of any arctic kit.
The nominal values related to the greater absorption configuration (measured during the operational phase at 6.6 A
with toroidal isolation transformer 65 W) are given in the table below:
Without Arctic Kit
With Arctic Kit
AC [W]
38 VA
55 VA
AR [R]
26 VA
43 VA
TG [G]
30 VA
47 VA
WG [G]
30 VA
47 VA
ER [R]
20 VA
37 VA
SB [R]
20 VA
37 VA
BA [R]
17 VA
34 VA
The power factor values are given in the table below: