DESCRIPTION
UT-MT-0812_2.0_24-01-2023 (EN)
Use and Maintenance Manual
LERA
13
2.4
Monitoring
On request, a light emission source status monitoring module integrated in the device is supplied. In the event
of a fault or failure it promptly returns the open circuit information to the secondary circuit of the isolation transformer.
2.5
Arctic kit
The arctic kit option meets the FAA specifications (Engineering Brief N.67) preventing the formation of ice on
the protective transparent glass by heating the body of the fixture near the glass.
The heater automatically activates when the temperature falls below -1 °C and is turned off when the detected
temperature is higher than +10 °C.
2.6
Article number
example: LERA
TG - P - 001 - 0 - A
Use [Colour]
AC
AR
TG
WG
ER
SB
BA
=
=
=
=
=
=
=
Axis and bar approach [White]
Side approach bars [Red]
Threshold [Green]
Wing bars [Green]
Runway end [Red]
Stop bar (FAA) [Red]
Stop bar ICAO [Red]
Configuration
P
C
=
=
Fixture complete with frangible coupling*
Fixture without frangible coupling**
Assembly
(P) With coupling
(C) Without coupling
001
= Complete fixture
000
050
250
=
=
=
without cable
with cable (0,50 m)
with cable (2,50 m)***
Monitoring option
0
M
=
=
Without monitoring
With monitoring
Arctic kit option
0
A
=
=
Without arctic kit
With arctic kit
*
Fixture equipped with special support, frangible coupling and cable with bipolar plug (L‑823)
**
Fixture equipped with special support. Support pole and frangible coupling that can be ordered separately
***
Cable length available only for AC use (axis and bar approach) and AR (side approach bars)
In the example
LERA - TG -P-001 - 0 - A
: High intensity elevated LED fixture, LERA model configured for threshold use. Unidirectional fixture with green colour
lamps. Complete system, equipped with special support, frangible coupling and cable with bipolar plug (L-823). Fixture not equipped with optional monitoring
system. Arctic kit present.