Operating Instruction and Documentation
4.80 H SST- 4.300 H SST
- 21 -
You can only work again with the automotive-lift, if it is in a safety-related perfect
condition.
• After it, carry out an reset as described in the operating instruction.
6.3 Reset the lift after an emergency lowering
A reset of the system can be enforced, if the Mobile column lift are in the lowest
position.
An access on the DIP-Switch can take place only with a switched off main switch
and only through instructed, authorized technical personnel.
a) There must not be a vehicle on the lift.
b) Remove the cover of the operating unit.
c) Remove the cover of the electrical box.
d) Press the button 1 (see pic. 5) and hold it.
e) Switch-off the main switch and wait 5 sec. Hold the reset button.
f) Switch-on the main switch and wait 5 sec. Hold the reset button.
g) Let go off the reset button.
h) Press the button „ lowering“ until both platforms are in the lowest position.
i) If necessary repeat several times the steps d) until h) so that the lift is surely in the
lowest position.
j) After that move the Dip-switch 7 on position „on“.
k) Dip-switch 5 stays on position „on“.
l) Repeat the steps d) until h)
m) After that, move the Dip-switch 7 on position „off“. Dip-switch 5 stays on position „on“.
n) On the computer-board must now three diodes lighten permanently. One additional
diode must be blinking in the frequency of approx. 1 sec.
o) Raise and lower the automotive lift a few times without load. Observe the process.
p) Mount the covers.
pic 5: controller
Summary of Contents for 4.120 H SST
Page 9: ...Operating Instruction and Documentation 4 80 H SST 4 300 H SST 9 2 5 CE Certificate ...
Page 10: ...Operating Instruction and Documentation 4 80 H SST 4 300 H SST 10 ...
Page 13: ...Operating Instruction and Documentation 4 80 H SST 4 300 H SST 13 3 3 Data sheet ...
Page 44: ...Operating Instruction and Documentation 4 80 H SST 4 300 H SST 44 Hydraulic diagram drawing ...