background image

17

•  Provide a ventilation opening just below the 

worktop of 4mm over a width of min. 600mm 
for sufficient cooling of the induction hob. Also 
provide sufficient air inlet under the appliance.

4. Install the insulation strip

 

 Do not turn the device over completely to 
prevent damage to the glass or failure of 
the components of the extraction tower.

Stick the insulation strip 2 mm from the outer edge 
at the rear side of the glass plate.

5. Install a bend for the exhaust duct

If the exhaust duct is mounted directly with a downward 
bend, first place the supplied bend on the unit. The 
connection for the exhaust duct is on the rear of the 
unit. Make the connection airtight with aluminium tape.

 
6. Install the unit

Place the unit in the opening provided. Firmly hold the 
cooking plate on the left and the right sides. Slightly 
tilt it and place the rear side into the openings. Then 
carefully lower the front side.
The duct can now be connected. For this follow the 
description in chapter 3.

 

3. INSTALL THE EXHAUST DUCT

3.1 Recirculation

In cases that do now allow for an exhaust duct to the 
outside, recirculation offers a solution. For this Novy 
offers an exhaust box with Monoblock recirculation filter. 
The exhaust box is the ideal solution for making the unit 
suitable for recirculation (drawing 7).

Exhaust box

The exhaust box is connected to the exhaust dust 
coming from the unit. The Monoblock recirculation filter 
is installed in the exhaust box. A choice can be made 
from the following exhaust box models (incl. Monoblock 
recirculation filter):

Typ

Model

Dim. 

(hxwxd)
(mm)

Duct  
connec-
tion

 
 
 
 
7921400  
7922400
7923400

Recirculation  
box H 98 with 
Monoblock filter 
White
Black
Stainless steel look

98 x 818 
x 290

222 x 89

 
 
 
7931400  
7932400
7933400

Recirculation box 
H 140 with Mono-
block filter
White
Black
Stainless steel look

140 x 
820 x 
292

222 x 89

3.2 Exhaust duct to the outside

The motor outlet has a rectangular exhaust of 220 x 90 
mm. It is recommended to connect an exhaust duct to 
this with the same dimensions (drawing 8).

For optimum performance of the hood it is important to 
pay attention to the items mentioned below.

When using a flat exhaust duct:

 

− Use flat ducts with rounded corners and air conductors 

in the bends. These ducts are to be obtained through 
Novy.

 

− An adapter makes it possible to change from a flat to 

a round exhaust duct.

When using a round exhaust duct:

 

− Use smooth, non-flammable pipes with an internal 

diameter that is equal to the external diameter of the 
connection nozzle of the hood. Maximally extend flexible 
ducts and cut them to size.

 

− Do not reduce the exhaust diameter. This will decrease 

the capacity and increase the noise level.

 

− When connecting to a short exhaust duct, it may be 

required to mount a non-return valve to prevent the 
wind from blowing in.

 

− Use a hose clamp or aluminium tape for airtight con-

nections.

 

− In case of an exhaust pipe through the outside wall, 

use the outside wall grate.

General:

 

− Make the duct as short as possible and with as few 

as possible bends to the outside.

 

− Avoid square bends. Use rounded bends for proper 

air conduction.

 

− If an exhaust pipe through the outside wall passes 

a cavity wall, make sure that the exhaust duct fully 
bridges the cavity and slightly declines to the outside.

 

− In case of an exhaust pipe through the roof, use a 

double-walled roof passage with sufficient width.

 

− Never connect the exhaust to a flue duct.

 

− Make sure that sufficient air is supplied. Fresh air can 

be supplied by slightly opening a window or an outside 
door or by installing an inlet grate.

Summary of Contents for 1801 One Power

Page 1: ...NL Montage instructie p 4 FR Instructions d installation p 9 DE Montageanleitung S 14 EN Mounting instructions p 19 1801 One Power 1811 One Pro 1801 1811 10530 MA2...

Page 2: ...1 2 3a 3b E F K P E F K P X Z 750 490 4 6 Min 55 Min 800 2 6 E F S T K P E F S T K P X R 750 490 784 524 4 6 Min 55 7 3c 3d 1801 1811...

Page 3: ...4 5 6 7 8 9 10...

Page 4: ...in de omgeving van de kookzones Dit magnetische veld kan elektronische apparatuur be nvloeden Neem bij twijfel contact op met de fabrikant van de pacemaker of met uw arts 1 3 Afvoer of recirculatie V...

Page 5: ...en incl monoblock filter Type Model Afm hxbxd mm Aanslui ting kanaal 7921400 7922400 7923400 Inbouwbox met monoblockfilter H 98 WIT H 98 ZWART H 98 INOX LOOK 98 x 818 x 290 222 x 89 7931400 7932400 79...

Page 6: ...plaats deze met een draaibeweging op de toren zie afbeelding 9 en 10 5 2 Gebruiksmodus apparaat Het toestel is standaard ingesteld om in recirculatiemodus te werken Indien u toch met afvoer naar buit...

Page 7: ...onderste zones gedurende 3 seconden Zodra de nieuwe beperking is geregistreerd weerklinkt een pieptoon 6 ACCESSOIRES Bij het toestel kunnen de volgende accessoires besteld worden Muurdoorvoer plat kan...

Page 8: ...ou du m decin 1 3 vacuation ou recyclage Avant de commencer le montage vous devez optez pour le r alisation d un conduit d vacuation ou pour un fonctionnement en mode recyclage Les r glages standard...

Page 9: ...Modele Dim h x l x p mm Raccorde ment Conduit 7921400 7922400 7923400 Caisson insonoris en castrable pour recyclage avec filtre monoblock H 98 BLANC H 98 NOIR H 98 COULEUR INOX 98 x 818 x 290 222 x 8...

Page 10: ...vercle en verre de la tour et posez le sur la tour en le tournant Sch ma 9 10 5 2 Modes d utilisation Le r glage standard de l appareil est celui du mode de recyclage Si toutefois vous optez pour une...

Page 11: ...ion des deux zones inf rieures pendant 3 secondes Une fois la nouvelle limite enregistr e un signal sonore retentit 6 ACCESSOIRES Les accessoires suivants sont disponibles sur commande Clapet de fa ad...

Page 12: ...erzschrittmacher in der N he des eingeschalteten Ger tes entsteht ein elektromag netisches Feld das eventuell den Herzschrittmacher beeintr chtigen w rde Wenden Sie sich bitte im Zwei felsfall an den...

Page 13: ...trieb des Ger ts Zeichnung 7 Umluftbox Die Umluftbox wird an den Abluftkanal angeschlossen der von dem Ger t ausgeht In der Umluftbox ist der Monoblock Filter angeordnet Es stehen die folgenden Umluft...

Page 14: ...den Turm nach oben zu bringen Nehmen Sie den Turm vollst ndig aus dem Kochfeld heraus indem Sie ihn nach oben heraus ziehen und legen Sie den Turm auf die Arbeitsplatte Nehmen Sie die lose Glasplatte...

Page 15: ...e Beschr nkung registriert ist ert nt ein Piepton 6 ZUBEH R Zu dem Ger t k nnen die folgenden Zubeh rteile be stellt werden Grillplatte Artikel 1700091 Mauerdurchf hrung flacher Kanal Inox Edelstahl i...

Page 16: ...The unit is supplied by default with settings for recirculation Chapter 3 includes an extensive explanation of the conditions for both systems 2 INSTALLATION Before installation read the general infor...

Page 17: ...ainless steel look 98 x 818 x 290 222 x 89 7931400 7932400 7933400 Recirculation box H 140 with Mono block filter White Black Stainless steel look 140 x 820 x 292 222 x 89 3 2 Exhaust duct to the outs...

Page 18: ...p Take the loose glass plate and place it with a turning movement onto the tower drawing 9 and 10 5 2 User modes The unit is by default set for operation in the recirculation mode If an exhaust to the...

Page 19: ...3 seconds Once the new limitation registered a beep will sound 6 ACCESSOIRIES The following accessories can be ordered with the unit Wall passage for flat duct Inox SS incl non return valve article 9...

Page 20: ...et les prix de ses produits Die NOVY AG beh lt sich das Recht vor zu jeder Zeit und ohne Vorbehalt die Konstruktion und die Preise ihrer Produkte zu ndern NOVY nv Noordlaan 6 B 8520 KUURNE Tel 056 36...

Reviews: