31
FIBER_TIGER_manual, 2021-11-29
CAUTION
Visible and/or invisible laser radiation
causes damage to eye or skin.
• Wear suitable protective glasses.
• Do not expose eyes and skin to direct, reflected or scattered laser radi-
ation.
• Set the laser power to the necessary minimum for adjustment.
reference groove
4.
Preparing for use
4.4. Commissioning
Procedure
1. Untighten the 8 screws (Torx, size 10), that are marked red in figure 4.17 on page
31, in a way that the adjusting ring from figure 4.18 on page 31 can be rotated.
2. Rotate the adjusting ring to set an angle that usually can be found on the fiber
manufacturer’s test report and check the result.
The graduation of the scale equals 1 mrad. The graduation is not equidistant.
Figure 4.17.: Eight fixing screws for tilting
Figure 4.18.: Adjusting ring for tilting