45
FIBER_TIGER_manual, 2021-11-29
NOTICE
Leaking cooling water
can cause a short circuit and/or damage optics.
• Get some tissues or similar ready in order to absorb leaking cooling water
immediately.
• Deposit the open tube tips in a way that cooling water cannot leak or
contain the cooling water in a tank.
CAUTION
Heavy weight
Risk of injury
• Work together with a second person.
7.
Decommissioning, returning and disposal
7.1. Decommissioning
2. Disconnect the electrical lines at the scan head at the interfaces DC INPUT 48 V,
ARN and SAFETY where applicable.
3. Disconnecting the purge gas:
a) Relieve the pressure from the hose.
b) Press the end piece of the quick connector down and pull the tube out.
4. Disconnecting the cooling water:
a) Relieve the pressure from the hoses.
b) At both cooling water quick connectors press the end piece of the quick con-
nector down and pull the tube out.
c) Take care of the now open cooling water lines to prevent cooling water from
leaking.
5. Dismount scan head:
a) Unfasten the 4 mounting screws.
b) Remove the scan head from the superordinate machine.