4.2 Board-to-Board Mounting
This section contains information needed for installing the Optira sensor to the customer's PCB.
Recommended Customer Required Parts
The following parts or their equivalents are recommended for the board-to-board mounting of the
Optira sensor.
Item
Description
Mounting Screws (2)
M1.6 or 0-80 screws. Philips head screws are recommended.
Do not use
slotted-head screws which can cause the screwdriver to slip and damage
components. Tighten screws per torque specification: 0.34 Nm (3 inch-lbs.)
maximum.
Caution
: Be careful tightening these screws to avoid damaging nearby
components.
PCB Mount Connector
1
Molex
®
part number 501591-1211: 0.40 mm (.016") pitch board-to-board
vertical mating receptacle. Mates to JP1 board-to-board connector (Molex
part number 501594-1211) on sensor.
Spacers (2)
Diameter cannot exceed keep-out area of 3.17 mm (see sensor dimensions
on Optira Interface Drawing). Height is .9 mm.
Surface Mount Fasteners (2)
MicroPEM
®
Fasteners, Type is SMTSO .060-80 (#0-80) or equivalent.
Note
1
: Header Mating: The header mating connector has a limited durability of 20 mating cycles
maximum.
Customer Bracket
Molex 501591-1211
Molex 501594-1211
Screws
Surface Mount Fasteners
Sensor
Bottom View
Spacers
Customer
Bracket