MicroE Optira Installation Manual
Celera Motion
IM-1001 | REV181211
Page 17
©2018 Celera Motion
J1 - ZIF Connector
Manufacturer Part Number: Hirose
®
FH33J-10S-0.5SH(10)
Pin
Number
Signal
A-quad-B
Analog
1
A+
SIN+
2
A-
SIN-
3
B+
COS+
4
B-
COS-
5
Index+
Index+
6
Index-
Index-
7
Alarm
Alarm
8
CAL
CAL
9
PWR
PWR
10
GND
GND
7.4 Recommended Signal Termination
Note:
Below values are applicable for 5 V models only.
Digital/Analog Outputs
Alarm
Circuit Example
Alarm output is an open collector
circuit that is factory programmable:
either active high or active low;
specify when ordering. Alarm requires
an external pull-up resistor. See
customer-supplied circuit example on
right.
Note:
Maximum cable length is 5 m. Contact MicroE Applications Engineering if longer lengths are
required.
J1 ZIF Connector
Optira Sensor Bottom View
R > Vcc
8mA
Vcc
≤ 5.5V
= 688
Ω
R > 5.5V
8mA
R
Vcc
P7
P10
Alarm