MicroE Optira Installation Manual
Celera Motion
IM-1001 | REV181211
Page 31
©2018 Celera Motion
Step
Action
2. Remove/peel the bottom adhesive backing:
•
Use a sharp tool or fingernails to start peeling the adhesive backing from the left end of the tape
scale.
•
Remove and peel back approximately 25 mm (1 inch) of the bottom adhesive backing, taking
care not to touch the adhesive or allow any particulate contamination.
Note
: Be careful not to expose the adhesive backing more than 50 mm (2 inches). Do not peel the
blue protective film off at this time.
3. Flip the tape over so that exposed adhesive surface of the tape scale (surface from which the
adhesive backing was removed) faces the surface where the tape will be attached.
Adhesive backing peeled off about 25 mm (1 inch) from the left end