MicroE Optira Installation Manual
Celera Motion
IM-1001 | REV181211
Page 14
©2018 Celera Motion
6.2 Install Optional Connector and Calibration Board
The optional Connector and Calibration Board can be connected to the sensor using cables in the
optional Development Kit or by using customer's wiring. Refer to the information in
Section 3.0
System Overview
.
Guidelines
•
The optional Connector and Calibration Board can be mounted by using mounting screws
and standoffs or epoxy.
•
Using Kapton tape is recommended if mounting directly to conductive surface without
standoffs.
•
Use the board as an indicator of alignment by monitoring the alarm LED. Refer to
Section 5.1.4 Sensor Head Alignment
to match Status Led on sensor and if Alarm LED
is configured as active high or active low.
Creating Custom Connector to Connector and Calibration Board
Use the crimping tool (JST YRS-859) with crimp connector terminals (JST SSH-003T-P0.2) to
connect custom cables to the mating connector (JST 10SR-3S) to J2 shrouded head connector
(JST SM10B-SRSS-TB).
Connector and Calibration Board
Connected to sensor using the
200mm FFC from the development kit
To customer's electronics
Connected to customer's electronics using the
3m controller cable from development kit
Sensor