29
The sensor configuration menu appears and it will show:
Sensor type
Model
Input
Calibration
Pressure
100-WS-16BP
A2
If you intend to add another sensor select "A".
If you do not want to add another sensor select "Q".
You will be asked if you are sure that you want to erase memory.
If you have added or deleted a sensor select "Y" if not select "N" and press "Enter".
Rain Gauge
Connect the rain gauge cable to the terminal strip on the data acquisition module. This
sensor has a two conductor cable. Connect one conductor to a GROUND terminal and
the other conductor to terminal P3.
INITIALIZATION OF THE RAIN GAUGE
Press "M" and "Enter" to get the main menu.
From the main menu press "1", Station setup.
From the station set up menu press "6", Add or remove sensors. Then press "Y", then
"Enter".
From the sensor type menu select "7", Precipitation.
From the precipitation menu select "1", All models. Then press "Enter".
From the sensor input channel select "3", Pulse Counter 3. Then press "Enter".
The screen directs you to: Enter tip resolution or press [Q] to quit. For English units, use
0.01. For metric units, use 0.254. Then press "Enter".
The sensor configuration menu appears and it will show:
Sensor type
Model
Input
Calibration
Precipitation
All models
P3
0.01
Note
: Changing units on the setup menu will not change the reported value for rainfall.
That change must be made from the add or remove sensors menu.
If you intend to add another sensor select "A".
If you do not want to add another sensor select "Q".
You will be asked if you are sure that you want to erase memory.
If you have added or deleted a sensor select "Y" if not select "N" and press "Enter".
Summary of Contents for 110-WS-16