26
APPENDIX 1 Sensor Configuration
The WS-16-A is configured at the factory for the sensors it is shipped with.
The
following instructions are provided to aid the user in making changes to the standard
setup.
Wind Speed and Direction
Connect the wind sensor cable to the terminal strip on the back of the data acquisition
module. This sensor has a four conductor shielded cable. The RED wire is connected
to the +5 REF terminal; The BLACK wire is connected to a GROUND terminal; the
GREEN wire (wind direction signal) is connected to the A7 terminal and the WHITE wire
(wind speed signal) is connected to the P1 terminal. The WS-16-A is now ready for
wind speed and wind direction initializing.
INITIALIZATION OF WIND SPEED AND DIRECTION SENSORS
Press "m” twice to get the main menu.
From the main menu press "1", Station set up.
From the station set up menu press "5", Add or remove sensors. Then press "Y", then
"Enter".
From the sensor types menu select "2", Wind Speed.
Select Units or Q to quit. (1-kph, 2- kt, 3- m/s, 4- mph)
From the wind speed sensors menu select "1", 200-WS-01/02. Then press "Enter".
From the sensor input channel select "1", P1 (Pulse Counter). Then press "Enter".
The sensor configuration screen is displayed and it will show:
Sensor type
Model Input
Units
Calibration
Wind Speed
200-WS-01/02 P1
MPH
If you intend to add another sensor select "A".
If you do not want to add another sensor select "Q".
You will be asked if you are sure that you want to erase memory.
If you have added or deleted a sensor select "Y" if not select "N" and press "Enter".
To initialize the wind direction sensor, press "M" and "Enter" to get the main menu.
From the main menu press "1", Station set up. Then press "Enter".