27
From the station set up menu press "6", Add or remove sensors. Then press "Y", then
"Enter".
From the sensor type menu select "3", Wind Direction. Then press "Enter".
From the wind direction sensor menu select "1", 200-WS-02. Then press "Enter".
From the sensor input channel menu select "11", Analog Input A7. Then press "Enter".
The sensor configuration menu appears and it will show:
Sensor type
Model
Input
Calibration
Wind Speed
200-WS-01/02
P1
Wind Direction
200-WS-02
A7
If you intend to add another sensor select "A".
If you do not want to add another sensor select "Q".
You will be asked if you are sure that you want to erase memory.
If you have added or deleted a sensor select "Y" if not select "N" and press "Enter".
Temperature (thermistor) and Relative Humidity (capacitive sensor)
Connect the combination temperature and relative humidity sensor cable to the terminal
strip on the back of the data acquisition module. This sensor has a five conductor cable.
The RED wire is connected to the +12 REF terminal. The BLACK wire is connected to a
GROUND terminal. The BROWN wire (humidity signal) is connected to the A4 terminal.
The WHITE (temperature signal) is connected to the A5 terminal and the GREEN wire
is connected to a GROUND terminal.
INITIALIZATION OF TEMPERATURE AND RELATIVE HUMIDITY
Press "M" and "Enter" to get the main menu.
From the main menu press "1", Station set up.
From the station set up menu press "6", Add or remove sensors. Then press "Y", then
"Enter".
From the sensor type menu select "4", Temperature. Then press "Enter".
From the temperature sensors menu select "2", 225-501/WS-16TH. Then press
"Enter".
The menu then asks: Enter temperature offset or press Q to quit. Press "Q".
From the sensor input channel menu select "9", A5. Then press "Enter".
Summary of Contents for 110-WS-16
Page 37: ......