SPOOL TORCH: Wear Parts & Torch Parts
May 25, 2022
Page 19
User Manual No: OM-10
4
A EN
5.03
SPOOL TORCH QLBF-200 III: Change Pressure Roll / Drive Roll
CHANGE Drive Roll (5)
a) Disconnect Power to the MIG/MAG equipment.
b)
Press Button
to lift the
Spool Cover
up to expose the
Wire Drive Mechanism.
c) Remove the
Welding Wire Spool
by:
K)
Hold Wire
against the
Spool
.
L)
Cut Wire
between the
Spool
&
Inlet Guide.
M) Put
Cut Wire End
from
Spool
into hole.
N) Unscrew the
Locking Screw.
O)
Pull the
Welding Wire End
out of the
Swan Neck
.
d) Rotate the
Pressure Arm Bolt (8)
counter-clockwise to
release the tension on the
Pressure Arm Assy.
e) Remove the
Pressure Arm Assy
by removing
Circlip (1)
using a suitable tool.
f) Unscrew
Allen Key Grub Screw (6)
then slide
Drive Roll
(5)
off the
Drive Shaft
.
g) Fit a new
Drive Roll (5)
then re-assemble the Spool
Torch.
CHANGE Pressure Roll (4)
a) Disconnect Power to the MIG/MAG equipment.
b)
Press Button
to lift the
Spool Cover
up to expose the
Wire Drive Mechanism.
c) Remove the
Welding Wire Spool
by:
K)
Hold Wire
against the
Spool
.
L)
Cut Wire
between the
Spool
&
Inlet Guide
.
M) Put
Cut Wire End
from
Spool
into hole.
N) Unscrew the
Locking Screw.
O)
Pull the
Welding Wire End
out of the
Swan Neck.
d) Rotate the
Pressure Arm Bolt (8)
counter-clockwise to
release the tension on the
Pressure Roll Bearing (4).
e) Remove the
Pressure Arm Assy
by removing
Circlip (1)
using a suitable tool.
f) Remove the
Circlip (2)
using a suitable tool.
g) Remove the
Roll Shaft (3)
then slide out the
Pressure
Roll (4)
.
h) Fit a new
Pressure Roll (4)
then re-assemble the Spool
Torch.