MCRM-S card replacement procedures
288
Meridian SL-100 SE Commercial Systems Card Replacement Procedures MSL15
NTMX77
in an MCRM-S RCC2
(continued)
At the MAP terminal
7
Busy the inactive PM unit by typing the following string:
> bsy unit rcc2_unit_no
and pressing the Enter key.
where
rcc2_unit_no
is the number of the inactive RCC2 unit (0 or 1)
At the RCC2 shelf
8
Put on a wrist strap.
9
Power down the MX72 power converter by setting the POWER
switch to the OFF position.
10
Unseat the MX73 card in slot 11 if working in unit 0 or in slot 17
if working in unit 1. Unseat the MX75 card in slot 10 if working in
unit 0 or in slot 18 if working in unit 1.
11
Locate the card to be removed on the appropriate shelf as
shown in the following figures.
CAUTION
Static electricity damage
Before removing any cards, put on a wrist
strap and connect it to the wrist strap
grounding point on the left side of the frame
supervisory panel of the RCC2. This protects
the equipment against damage caused by
static electricity.
CAUTION
Equipment damage
When inserting or removing a card, do not
apply direct pressure to the components or
force the cards into the slots.
Summary of Contents for Meridian SL-100 SE
Page 2: ......
Page 4: ......
Page 6: ...vi Publication history 555 4031 547 Standard 12 02 July 2002...
Page 10: ...x Contents 555 4031 547 Standard 12 02 July 2002...
Page 46: ...46 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 56: ...56 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 72: ...72 FSP card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 80: ...80 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 96: ...96 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 108: ...108 IPE card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 120: ...120 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 138: ...138 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 149: ...149 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 150: ...150 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 160: ...160 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 187: ...187 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 188: ...188 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 198: ...198 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 208: ...208 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 218: ...218 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 228: ...228 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 252: ...252 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 294: ...294 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 320: ...320 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 322: ...322 MCRM S card replacement procedures 555 4031 547 Standard 12 02 July 2002...
Page 337: ......