NT8D15 E&M Trunk card
Page 645 of 906
Circuit Card
Description and Installation
Incoming calls
The far-end initiates calls as follows:
•
The ground is placed on the E lead in E&M signaling.
•
Dial pulses are subsequently applied from the far-end as ground open on
the E lead.
•
If the far-end is equipped for sending, the system can operate in any
mode (immediate start, delay dial, or wink start), as assigned on a start
arrangement basis. See Table 197.
— In immediate start mode, there is no start signal from the called
office. The seizure signal (off hook supervisory state) from the
far-end should be at least 150 ms. At the end of the seizure signal,
the far-end can start pulsing after the standard delay (normally 70 ms
minimum).
— In delay dial mode, a 256–384 ms off hook/on hook signal is
returned to the far-end immediately after receipt of the seizure
signal. When the far-end detects the on hook signal (start signal), the
far-end can start pulsing after the standard delay (normally 70 ms
minimum).
— In wink start mode, within a 128–256 ms period after receipt of the
seizure signal from the far-end, the called office transmits a 250 ms,
wink start, off hook/on hook signal to the calling office.
E&M Type II signaling
Figure 151 on
page 647
shows E&M Type II signaling patterns for incoming
and outgoing calls. Figure 152 on
page 648
shows Type II signaling patterns
Table 197
Operation Mode
Operation mode
Start arrangement
Immediate start
IMM
Delay dial
DDL
Wink start
WNK
Summary of Contents for Circuit Card
Page 2: ......
Page 4: ...Page 4 of 906 Revision history 553 3001 211 Standard 3 00 August 2005...
Page 18: ...Page 18 of 906 Contents 553 3001 211 Standard 3 00 August 2005...
Page 78: ...Page 78 of 906 Overview 553 3001 211 Standard 3 00 August 2005...
Page 100: ...Page 100 of 906 Acceptance tests 553 3001 211 Standard 3 00 August 2005...
Page 156: ...Page 156 of 906 Option settings 553 3001 211 Standard 3 00 August 2005...
Page 192: ...Page 192 of 906 NT4N39AA CP Pentium IV Card 553 3001 211 Standard 3 00 August 2005...
Page 378: ...Page 378 of 906 NT5K21 XMFC MFE card 553 3001 211 Standard 3 00 August 2005...
Page 384: ...Page 384 of 906 NT6D70 SILC Line card 553 3001 211 Standard 3 00 August 2005...
Page 388: ...Page 388 of 906 NT6D71 UILC Line card 553 3001 211 Standard 3 00 August 2005...
Page 544: ...Page 544 of 906 NT8D02 and NTDK16 Digital Line cards 553 3001 211 Standard 3 00 August 2005...
Page 546: ...Page 546 of 906 NT8D03 Analog Line card 553 3001 211 Standard 3 00 August 2005...
Page 564: ...Page 564 of 906 NT8D09 Analog Message Waiting Line card 553 3001 211 Standard 3 00 August 2005...
Page 626: ...Page 626 of 906 NT8D14 Universal Trunk card 553 3001 211 Standard 3 00 August 2005...
Page 720: ...Page 720 of 906 NTAK09 1 5 Mb DTI PRI card 553 3001 211 Standard 3 00 August 2005...
Page 734: ...Page 734 of 906 NTAK10 2 0 Mb DTI card 553 3001 211 Standard 3 00 August 2005...
Page 744: ...Page 744 of 906 NTAK20 Clock Controller daughterboard 553 3001 211 Standard 3 00 August 2005...
Page 762: ...Page 762 of 906 NTAK79 2 0 Mb PRI card 553 3001 211 Standard 3 00 August 2005...
Page 772: ...Page 772 of 906 NTBK22 MISP card 553 3001 211 Standard 3 00 August 2005...
Page 844: ...Page 844 of 906 NTVQ01xx Media Card 553 3001 211 Standard 3 00 August 2005...
Page 850: ...Page 850 of 906 NTVQ55AA ITG Pentium card 553 3001 211 Standard 3 00 August 2005...
Page 884: ...Page 884 of 906 QPC841 Quad Serial Data Interface card 553 3001 211 Standard 3 00 August 2005...
Page 907: ......