
Overview
Page 51 of 906
Circuit Card
Description and Installation
•
In order to detect distant end disconnect for calls terminating on the
lineside T1 card, the hook flash feature within the SAL software must be
enabled.
•
In order to detect distant end disconnect for calls originating and
terminating on the lineside T1 card, both the battery reversal and hook
flash features must be enabled within the SAL software.
Call disconnect from lineside T1 terminal equipment
Alternatively, while a call is in process, the terminal equipment may
disconnect by going on-hook. The terminal equipment detects no loop current
and sends signaling to the lineside T1 card that causes its receive A bit to
change from 1 to 0. The call is now released.
Table 4 outlines the lineside T1’s A and B bit settings in each state of call
processing.
Table 4
Loop Start Call Processing A/B Bit Settings (Part 1 of 2)
State
Transmit
Receive
A
B
A
B
Idle
0
1
0
1
Incoming Calls:
•
Idle
0
1
0
1
•
Ringing is applied from lineside T1 card
0
1/0
0
1
•
Terminal equipment goes off-hook
0
1/0
1
1
•
Lineside T1 card stops ringing
0
1
1
1
Outgoing Calls:
•
Idle
0
1
0
1
•
Terminal equipment goes off-hook
0
1
1
1
Call Disconnect from far end:
Summary of Contents for Circuit Card
Page 2: ......
Page 4: ...Page 4 of 906 Revision history 553 3001 211 Standard 3 00 August 2005...
Page 18: ...Page 18 of 906 Contents 553 3001 211 Standard 3 00 August 2005...
Page 78: ...Page 78 of 906 Overview 553 3001 211 Standard 3 00 August 2005...
Page 100: ...Page 100 of 906 Acceptance tests 553 3001 211 Standard 3 00 August 2005...
Page 156: ...Page 156 of 906 Option settings 553 3001 211 Standard 3 00 August 2005...
Page 192: ...Page 192 of 906 NT4N39AA CP Pentium IV Card 553 3001 211 Standard 3 00 August 2005...
Page 378: ...Page 378 of 906 NT5K21 XMFC MFE card 553 3001 211 Standard 3 00 August 2005...
Page 384: ...Page 384 of 906 NT6D70 SILC Line card 553 3001 211 Standard 3 00 August 2005...
Page 388: ...Page 388 of 906 NT6D71 UILC Line card 553 3001 211 Standard 3 00 August 2005...
Page 544: ...Page 544 of 906 NT8D02 and NTDK16 Digital Line cards 553 3001 211 Standard 3 00 August 2005...
Page 546: ...Page 546 of 906 NT8D03 Analog Line card 553 3001 211 Standard 3 00 August 2005...
Page 564: ...Page 564 of 906 NT8D09 Analog Message Waiting Line card 553 3001 211 Standard 3 00 August 2005...
Page 626: ...Page 626 of 906 NT8D14 Universal Trunk card 553 3001 211 Standard 3 00 August 2005...
Page 720: ...Page 720 of 906 NTAK09 1 5 Mb DTI PRI card 553 3001 211 Standard 3 00 August 2005...
Page 734: ...Page 734 of 906 NTAK10 2 0 Mb DTI card 553 3001 211 Standard 3 00 August 2005...
Page 744: ...Page 744 of 906 NTAK20 Clock Controller daughterboard 553 3001 211 Standard 3 00 August 2005...
Page 762: ...Page 762 of 906 NTAK79 2 0 Mb PRI card 553 3001 211 Standard 3 00 August 2005...
Page 772: ...Page 772 of 906 NTBK22 MISP card 553 3001 211 Standard 3 00 August 2005...
Page 844: ...Page 844 of 906 NTVQ01xx Media Card 553 3001 211 Standard 3 00 August 2005...
Page 850: ...Page 850 of 906 NTVQ55AA ITG Pentium card 553 3001 211 Standard 3 00 August 2005...
Page 884: ...Page 884 of 906 QPC841 Quad Serial Data Interface card 553 3001 211 Standard 3 00 August 2005...
Page 907: ......