AS 5300 initial software deployment
69
The system displays a list of loads and prompts for a load
selection.
3
Select the load for installation.
The system displays a list of staging files and prompts for user
selection:
Please enter number [1 to 10] of selection:
4
From the list of staging files, enter the number of the staging file
to use.
Attention:
Select either StagingFedPBX2Server or
StagingFedPBX4Server for AS 5300 deployments.
5
Change directory:
cd var/mcp/install
6
Run the script to populate the installProps file:
populateInstallpropsFile.pl
7
Enter the information as prompted.
Attention:
Select X3550_Micro (small) or X3550_Standard
(medium) configuration for AS 5300.
An "Installprops.txt Updated Successfully" message appears.
8
Run the script to populate the tags file:
populateTagsFile.pl -t <tags_file>
Attention:
Select either StagingFedPBX4Server.tags or
StagingFedPBX2Server.tags for AS 5300.
A "StagingFedPBX<x> Server.tags" success message appears.
9
Enter the information as prompted.
--End--