38
Hardware installation and configuration
25
Select Exit Setup and select Yes when prompted for
confirmation.
--End--
Configuring the ServeRAID BIOS
Use this procedure to configure the ServeRAID BIOS.
Prerequisites
•
The ServeRAID BIOS has been reset to the factory default settings.
Procedure Steps
Step
Action
1
Reboot the server.
The server restarts and the following message displays:
Press CTRL-A for IBM ServeRAID Configuration
Utility
2
Press CTRL+A.
The IBM ServerRAID Configuration Utility screen appears.
3
Select SerialSelect Utility.
4
Select Controller Configuration.
5
Select Drives Write Cache.
6
Choose SATA Off, SAS Off.
7
Press Esc to return to the previous menu.
8
Select Yes to the Save Changes Made prompt.
9
Press Esc to return to the ServeRAID Configuration Utility
menu.
10
Select Array Configuration Utility.
11
Press C to create an array.
The Select drives to create Array window appears.
The Selected Drives list should be empty.
12
Highlight the first disk and press Ins.
The selected disk is added to the right window and the second
drive is now highlighted.
13
Press Ins to insert the second drive into the list.
The second drive is included in the Selected Drives list.
14
Press Enter.
Application Server 5300
Nortel AS 5300 Installation
NN42040-300
01.04
4 November 2008
Copyright © 2007-2008 Nortel Networks
.
Summary of Contents for Application Server 5300
Page 123: ......