34
Hardware installation and configuration
WARNING
The resetting of the ServeRAID BIOS to factory defaults
includes the destruction of all currently defined RAID arrays.
This results in the deletion of all data on the disk drives and
requires reinstallation of all server software.
Procedure Steps
Step
Action
1
Reboot the system.
The system displays the following message:
Press CTRL-A for IBM ServeRAID Configuration
Utility
2
Press CTRL+A .
The IBM ServerRAID Configuration Utility screen appears.
3
Delete any existing arrays (if configured during previous
installations) by doing the following:
•
Select Array Configuration Utility.
•
Press M to select Manage Arrays.
— If the message
No Arrays present
appears, there are
no arrays configured. Press Esc to return to the top-level
menu and continue with step 4.
— Otherwise, the List of Arrays appears.
•
Highlight the array and press Del to delete it.
•
Select Delete.The system displays the following prompt:
WARNING: Deleting will erase all data from the
array.
Do you still want to continue?
(Yes/No)
•
Press Y to continue.
•
Press Esc twice to return to the top-level menu.
4
Select SerialSelect Utility.
5
Select Controller Configuration.
6
Press F6 to reset to factory defaults.
7
Select Yes to reset the ServeRAID BIOS to default.
8
Press Esc to return to the previous menu.
The system displays the following prompt:
Save changes made?
(Yes/No)
9
Select Yes to save changes.
10
Select PHY Configuration.
Application Server 5300
Nortel AS 5300 Installation
NN42040-300
01.04
4 November 2008
Copyright © 2007-2008 Nortel Networks
.
Summary of Contents for Application Server 5300
Page 123: ......