Installing the firmware upgrades
103
The IBM Flash Update Utility appears.
5
Select 1 to update the BIOS.
6
Reply Y to move the current image to the backup location within
the Flash ROM.
7
Reply N to update the serial number.
8
Reply N to update the Type/Model
9
Reply N to update the Asset Tag Number.
10
Reply N to save the current image to disk.
11
Enter 1 to update the firmware.
The system displays the following message:
Flashing BIOS. May take up to 30 seconds.
12
Remove the CD from the CD-ROM drive.
13
Press Enter to reboot.
--End--
Installing Base Management Controller (BMC) firmware upgrades
Use this procedure to install upgrades to the BMC firmware. This
procedure requires the reboot of the server.
Prerequisites
•
You must be assigned to the SSA role (ntsysadm).
•
You must have the CD containing the BMC firmware upgrade file.
Procedure Steps
Step
Action
1
Load the BMC firmware upgrade CD into the CD-ROM drive.
2
Log on to the server as the SSA role (ntsysadm).
3
Reboot the server.
sudo reboot
4
If the operating system has been installed, change the boot
sequence so that the CD-ROM is the primary boot device by
doing the following:
•
When the BIOS information appears, press F12 to select the
boot sequence.
•
Select CD-ROM as the primary boot device.
Otherwise, wait for the server to reboot.
Application Server 5300
Nortel AS 5300 Installation
NN42040-300
01.04
4 November 2008
Copyright © 2007-2008 Nortel Networks
.