218
Switch administration tasks
Field
Description
SerNum
Displays the individual switch serial
number.
AuthenticationTraps
Click enable or disable. When you
select enabled, SNMP traps are sent
to trap receivers for all SNMP access
authentication. When you select disabled,
no traps are received.
To view traps, click the Trap toolbar
button.
Reboot
Action object to reboot the agent.
Reset - initiates a hardware reset.
The agent attempts to return a response
before the action occurs. If any of
the combined download actions are
requested, neither action occurs until the
expiration of s5AgInfoScheduleBootTime,
if set.
AutoPvid
Click enabled or disabled. When you
select enabled, Port VLAN ID (PVID) is
automatically assigned.
ManagementVlanId
The current management VLAN ID.
StackInsertionUnitNumber
The unit number to be assigned to the
next unit that joins the stack. You cannot
set the value to the unit number of an
existing stack member. When a new
unit joins the stack, and the value of this
object is used as its unit number, the
value reverts to 0. If the value of this
object is 0, it is not used to determine the
unit number of new units.
AutoUnitReplacement
Enabled
Determine whether auto-unit-replacement
is enabled or disabled.
NextBootMgmtProtocol
The transport protocols to use after the
next boot of the agent.
CurrentMgmtProtocol
The current transport protocols that the
agent supports.
Nortel Ethernet Routing Switch 4500 Series
Overview — System Configuration
NN47205-500
02.01
Standard
5.0
23 February 2007
Copyright © 2007, Nortel Networks