Powder Pilot
™
HD
P/No.7192721_02
Page | 19
9
–
mover control
–
Pressing this area on the main screen displays the mover control page as shown
below :-
Mover adjustment
Auto / Manual selector
Max Outer limit
Max inner limit
Current position
Manual Mover out
Manual Mover in
Exit
Mover adjustment
–
This field displays the offset value that determines the actual distance of the
guns from the conveyor centre line As an example, if the gun is actually 500mm from the conveyor
centre line, but the screen displays only 440mm, adding 60 to the adjust value will correct the position
display .
Note This value was set up during commissioning and should only be modified by authorised
personnel. Therefore, this entry has been password protected
Auto / manual selector
–
This button toggles between mover auto and manual control In auto mode,
the mover profiles around any product that enters the booth maintaining a fixed distance from the work
This value is set up on the main screen (See main screen elements
4
)
In manual mode (denoted by the symbol of a hand on a yellow background), the mover stays where it
is and only moves in and out between the ultimate limits by the operator pressing either key D1 to
move in or E1 to move out of the booth
CAUTION
–
The operator has total responsibility for the operation of the movers when in manual
control Permanent gun damage may occur if running in manual and the guns have not been set
correctly to spray the product entering the booth
maximum outer limit
–
This value displays the maximum position that the mover can withdraw to in
millimetres (This value is set in the configuration screen and is represented as the distance from the gun
nozzle to the conveyor centre line)
current mover position
–
This displays the current gun position in relation to the conveyor centre line
maximum inner limit
–
This value displays the maximum position that the mover can move in to in
millimetres (This value is set up in the configuration screen and is represented as the distance from the
gun nozzle to the conveyor centre line)
mover out
–
This button when pressed will drive the mover out as long as manual control is selected
mover in
–
This button when pressed will drive the mover in as long as manual control is selected
exit
–
This button closes the mover control window