8, 9
–
Mover encoder resolution
–
enoder resolution of movers 1 and 2 are entered here in pulses per
mm
10 -
Movers in
–
This is the ultimate in position that the movers will be allowed to go to
11 -
Movers purge
–
This is the purge and park position for the movers
12 -
Movers out
–
This is the maximum out position that the movers will be allowed to go to
13 -
Automatic mover speed
–
This is the speed at which the movers will traverse during normal
production mode. The value is entered as a percentage.
14 -
Clean mover speed
–
This is the speed at which the movers will travel out during the external gun
blow off phase of the cleaning cycle The value is entered as a percentage.
15 -
airwash on time
–
This is the time in seconds that the booth air wash will be on for
16 -
airwash off time
–
This is the time in seconds that the booth air wash will be off for
17 -
Booth end from arrays
–
This is the distance in millimetres from the beam arrays to the end of the
booth.
18 -
Booth start to arrays
–
This is the distance in millimetres from the beam arrays to the entrance of
the booth.
19
–
Pump card calibration
–
this symbol is used to bring up the pump card calibration window as
described separately.
20
–
Purge timing configuration
–
this symbol is used to display the set up window for the purge timings
used by the Spectrum
HD
for cleaning of guns and hopper. Details are described separately.
21 -
Horizontal array
–
This is the length of the horizontal beam array.
22 -
Dampen near
–
This is the width of the conveyor track left of the centre line.
Note :
The display to the right of this entry is the actual left hand width in millimetres, of any product
sensed in the beam array
23 -
Dampen far
–
This is the width of the conveyor track right of the centre line.
Note:
The display to the right of this entry is the actual right hand width in millimetres, of any product
sensed in the beam array
24
–
31
–
Gun PEC zone assignment
–
Guns 1 (P1) up to Gun 8 (P8) will be assigned to the 8 available
digital beam array zones. As soon as a dedicated zone is covered in the array, the assigned gun will be
triggered In the example above guns 1 + 2 are assigned to zone 1, guns 3 + 4 to zone 2 and so on.