Powder Pilot
™HD
P/No.7192721_02
Page | 22
GUN SET POINT STATUS SCREEN
By pressing the button keyed as
E
located on the main screen, the system will display the guns triggered
status page as shown below:-
A
–
exit screen
B
1 2 3
A
–
exit
–
This button exits the gun configuration screen and returns to the main screen.
B
–
gun feedbacks
–
This button
displays the actual gun feedback screen as described separately.
1
–
gun 1 powder set point
–
This bar displays the current powder set point value applied to gun 1. Its
units are displayed as a percentage value
2
–
gun 1 pattern air set point
–
This bar displays the current pattern air set point value applied to gun 1.
Its units are displayed in Standard Cubic Meters per hour (SCMH).
3
–
gun 1 KV set point
–
This bar displays the current voltage set point value applied to gun 1. Its units
are displayed in Kilo Volts.