Powder Pilot
™HD
P/No.7192721_02
Page | 28
5
–
horizontal distance
–
This value shows the distance between the gun and the beam array in
millimetres Touch the value and a keypad will appear to adjust it.
6
–
total gun hours
–
This displays the total hours that the gun has triggered for If the gun is
replaced, this number can be reset by touching the display and entering zero into the keypad that will
appear.
7
–
total pump hours
–
This displays the total hours that the pump has triggered for If the pump is
serviced, this number can be reset by touching the display and entering zero into the keypad that will
appear.
8
–
fast pump mode selection
–
touching this symbol will toggle the pump mode
between fast
and
normal pinch valve frequency
Note:
this is a global setting and will apply to all guns of the system
9
–
total guns
–
This value shows the total number of guns on the system
10
–
gun prime time
–
This value shows the time that the guns will fire for when the booth has been
stood empty and the first product enters the booth. This value is entered in seconds.
11
–
Maintenance alarm time
–
This value shows the time after which an alarm will be displayed for
any pump that has run for longer than it. This value is entered in hours.