Powder Pilot
™
HD
P/No.7192721_02
Page | 16
D
–
guns triggered display
–
This button displays a screen with an overview of which guns are
triggered This screen is detailed in a later section of this manual
E
–
gun feedback display
–
This button displays the gun set point and actual feedback screen All set
and running spray values for each gun are displayed here This screen is detailed in a later section of
this manual
F
–
gun spray control
–
This button displays the gun spray control page From here, the guns flow,
atomising pressures and KV can be adjusted as well as gaining access to the guns positional
dimension control
Full details are described in a later section of this manual
G
–
booth lights
–
This button turns the booth lights on or off Each subsequent press of this button
toggles the lights state between on and off
H
–
gun pressure trim
–
This button when pressed, reveals a pop up window to control the
percentage offset that will be applied to the powder and pattern air set points
I
–
mute
–
Any fault that occurs with the system will enable an audible Klaxon alarm to attract the
operators’ attention to the fault Pressing this key silences the alarm The
yellow light within the light
stack will continue to illuminate until the fault is cleared
J
–
alarm summary
–
All faults are logged with a time & date at which they occurred
Pressing this button will display an alarm log showing a brief description of the fault and its current
status If the status shows as K, then the alarm is active If the alarm is listed with a status of K(G), the
alarm is cleared
Pressing the “
” in the top right hand corner of this screen will exit the log
K
–
configuration
–
This button jumps to the configuration screen The booth system parameters can
be adjusted from here
Note:- This screen is only adjusted occasionally and by authorised personnel only Therefore, this
screen has been password protected
A subsequent section of this manual details the parameters available from this screen
L
–
shut down
–
touching this button will close all applications and shuts down the PC
Important:
before switching off the system use this function to securely disable the soft-PLC and save
all data stored in its memory.
Stay patient before switching off power.