PRE-OPERATION
BC 60 "Trailblazer" Brushcutter
Section 2-6
DEC/2012 (49458202/8203)
Instrument or Control
Type of Control
Functional Description
Warning Light
Amber LED
LED
status lights are
located on the upper
left and upper right
sides of the powerview.
When they are lit, the
screen will tell you the
fault, the code number
for the fault, and the
method to correct the
fault.
The Amber Warning LED signals an ACTIVE FAULT
code. When the light comes on, an abnormal
condition exists. It is not necessary to shut down
the engine immediately, but problem should be
corrected as soon as possible. This light will
remain on until all faults are corrected. Note: There
may be more than one fault if <NEXT or MORE>
appears at the bottom of the screen. You can also
hide the faults by hitting the ENTER key. (Hitting
the enter key again will take you back to the fault).
NOTE: Ignoring active fault codes (warnings or
shutdown) could result in severe engine damage.
Shutdown Derate Light
Red LED
LED
status lights are
located on the upper
left and upper right
sides of the powerview.
When they are lit, the
screen will tell you the
fault, the code number
for the fault, and the
method to correct the
fault.
The Red Shutdown Derate LED signals a fault has
occurred that requires immediate action. Shutdown
the engine, but do not turn the switch to the off
position. You must go through the codes on the
screen and correct the problems prior to restarting
the engine. (The Powerview remembers the errors).
NOTE: Ignoring active fault codes (warnings or
shutdown) could result in severe engine damage.
Screen Display
Used to monitor engine and engine controls.
HIDING FAULTS AND WARNINGS
If you have hidden (hit the ENTER key at any fault condition), and have returned to the original 4-Up (or 1-Up)
screen, the screen will now show icons in the upper right hand corner of a 1-UP screen or in the middle of the 4-UP
screen (see figure below) to show you where the faults occurred. (In the 4-up shown below, the exclamation point
appears in the middle and at the status that is showing a fault – the oil pressure.) Remember, the screen will show a
<NEXT or MORE> if more than one error has occurred.
Scroll through the screen until you find the individual component that has a fault.
Highlight the component and press the ENTER key to read the fault.
Each fault icon has a different meaning and different methods to correct. These are:
NOTE: Faults can only be cleared when the fault has been corrected.
SHUTDOWN MACHINE as soon as possible when you have encountered a
Shutdown Fault.
Summary of Contents for Trailblazer BC60
Page 2: ......
Page 48: ...BC 60 Trailblazer Brushcutter MAINTENANCE AUGUST 2012 49458202 8203 Section 3 3...
Page 49: ...MAINTENANCE BC 60 Trailblazer Brushcutter Section 3 4 AUGUST 2012 49458202 8203...
Page 64: ...BC 60 Trailblazer Brushcutter MAINTENANCE MARCH 2011 49458201 Section 3 21 TORQUE REQUIREMENTS...