8.1 Electromagnetic compatibility (EMC)
If the device is installed according to the recommendations in this manual, it meets all EMC directive
requirements, as per the EMC product standard EN 60947-4-2.
8.1.1 General Provisions
As of July 2007, all electrical equipment which has an intrinsic, independent function and which is sold
as an individual unit for end users, must comply with Directive 2004/108/EEC (formerly Directive
EEC/89/336). There are three different ways for manufacturers to indicate compliance with this
directive:
1
.
E
U
Declaration of Conformity
This is a declaration from the manufacturer, stating that the requirements in the applicable
European standards for the electrical environment of the equipment have been met. Only those
standards which are published in the Official Journal of the European Community may be cited in
the manufacturer’s declaration.
2
.
Technical documentation
Technical documentation can be produced which describes the EMC characteristics of the device.
This documentation must be authorised by one of the “Responsible bodies” named by the
responsible European government. This makes it possible to use standards which are still in
preparation.
3
.
E
U
Type test certificate
This method only applies to radio transmitter equipment.
The devices only have an intrinsic function when they are connected to other equipment (e.g. to a
motor). The base units cannot therefore carry the CE mark that would confirm compliance with the
EMC directive. Precise details are therefore given below about the EMC behaviour of this product,
based on the proviso that it is installed according to the guidelines and instructions described in this
documentation.
The manufacturer can certify that his equipment meets the requirements of the EMC directive in the
relevant environment with regard to their EMC behaviour in power drives. The relevant limit values
correspond to the basic standards EN 61000-6-2 and EN 61000-6-4 for interference immunity and
interference emissions.
8.1.2 EMC evaluation - EN 55011-1 (environmental standard)
The limits are defined in dependence on the basic environment in which the product is operated in this
standard. A distinction is made between 2 environments, whereby the
1st environment
describes the
non-industrial
living and business area
without its own high-voltage or medium-voltage distribution
transformers. The
2nd environment
, on the other hand, defines
industrial areas
which are not
connected to the public low-voltage network, but have their own high-voltage or medium-voltage
distribution transformers. The limits are subdivided into
classes A and B
.
Summary of Contents for NORDAC START Series
Page 1: ...BU 0135 en NORDAC START SK 135E SK 175E Users Manual for Motor Starters...
Page 4: ...NORDAC START SK 135E SK 175E Users Manual for Motor Starters 4 BU 0135 en 4118...
Page 111: ...8 Additional information BU 0135 en 4118 111 8 1 4 EU Declaration of Conformity...
Page 119: ...Key word index BU 0135 en 4118 119...
Page 120: ...6071302 4118...