29
2.
Remove the electrical panel from the right-hand side of the sprayer to and locate
the access hole on the top right hand side.
Electrical Panel
BOTTOM (view from panel)
TOP (view from cab)
3-PIN Pwr Connection
Figure 26 – UC4 Power Cable Routing
3.
Connect the UC4 Power Cable B (
Item C10 B
) to the UC4 Control Panel (
E1
) in
the sprayer cab (
Figure 27
). The 3-pin AMP plug on
C10 B
is connected to the
auxiliary power connection in the sprayer cab.
NOTE: Ensure the UC4 Control Panel’s power is OFF for the remaining
installation (Bottom of switch pressed IN).
4.
Connect the Sensor Trunk Cable (
Item C1
) to the UC4 Control Panel with the 4-
pin AMP connector. Route this through the access hole as well into the electrical
panel.
5.
On the left side of the electrical panel (
Figure 26
), there is a knockout. Remove
the knockout and install the grommet (
Item M15
). The grommet may fit easier
if it is cut radially (ie. like a lockwasher).
6.
Route the Jam Valve Cable (
Item C11
) through the grommet.
Grommet
w/knockout
Access Hole
Access
Hole
Access
Hole
Summary of Contents for SPRA-COUPE 7000 Series
Page 9: ...7 Figure 3 Hydraulic Plumbing Schematic ...
Page 17: ...15 Figure 9 Spra Coupe Wing Sensor Mounting ...
Page 21: ...19 Figure 14 Installation Details ...
Page 27: ...25 Figure 21 Valve Block Mounting Location Figure 22 Valve Block Mounting Example ...
Page 29: ...27 Figure 23 Boom Cylinder Plumbing ...
Page 37: ...35 5 3 ITEM C3 44656 VALVE CABLE VARIABLE RATE 5 4 ITEM C4 44651 VALVE EXTENSION CABLE ...
Page 38: ...36 5 5 ITEM C10 44650 38 POWER CABLE SPRA COUPE 7000 CABLE A ...
Page 39: ...37 5 6 ITEM C10 44650 38 POWER CABLE SPRA COUPE 7000 CABLE B ...
Page 40: ...38 5 7 ITEM C11 44658 15 JAM VALVE CABLE SPRA COUPE 7000 ...
Page 41: ...39 NOTES ...
Page 42: ...40 NOTES ...