
12
d)
Compress and install the spring between the collar and the upper ring of the
base.
e)
Install the tube as shown and, for now, lightly tighten collar around the tube.
You will need to aim the sensor bracket later.
2.
In order to reduce the chance of problems, inspect the booms in their folded
position. Mark the locations where the sensor brackets can be mounted
without
contacting the sprayer
. Then the booms can be unfolded and the sensors
mounted without having any mechanical interference.
NOTE: If possible, mount the sensor brackets while the booms are in
their folded position to ensure that the sensor and bracket will
not interfere with anything when the boom is folded for
transport.
NOTE: Please be aware of the maximum length of the sensor branch
cable (
Item C2
) for each branch. Note that the sensors can not
be mounted outside of this range on each boom. It might be
wise to route the branch cable at this time to ensure that the
cable reaches to the sensors. (Please refer to Section 4.6
Electrical Installation).
IMPORTANT:
Provide enough slack in the sensor branch cable to account for
the movement of the main section, parallel lift, and FOLDING
boom movement.
3.
Mount one NORAC UC4 ultrasonic sensor (
Item E2
) near the tip of each boom
with the brackets provided (
Item B13
). Using the 8-mm nuts and lock washers
provided with the sensor to attach the sensor to the bracket. The sensors should
be oriented forward (ahead) of the boom.
General mounting rules for UC4 ultrasonic wing sensors:
•
When the boom is in its lowest position, the sensor mouth must be 9 inches or
more from the ground.
•
The bottom of the sensor must be at least 9 inches in front of the spray
nozzles.
•
The bottom of the sensor must be at least 9 inches above the spray nozzles.
•
The sensor should be approximately vertical at normal operating heights.
•
Ensure that there are no obstructions within a six-inch diameter circle
projected directly below the center of the sensor.
Summary of Contents for SPRA-COUPE 7000 Series
Page 9: ...7 Figure 3 Hydraulic Plumbing Schematic ...
Page 17: ...15 Figure 9 Spra Coupe Wing Sensor Mounting ...
Page 21: ...19 Figure 14 Installation Details ...
Page 27: ...25 Figure 21 Valve Block Mounting Location Figure 22 Valve Block Mounting Example ...
Page 29: ...27 Figure 23 Boom Cylinder Plumbing ...
Page 37: ...35 5 3 ITEM C3 44656 VALVE CABLE VARIABLE RATE 5 4 ITEM C4 44651 VALVE EXTENSION CABLE ...
Page 38: ...36 5 5 ITEM C10 44650 38 POWER CABLE SPRA COUPE 7000 CABLE A ...
Page 39: ...37 5 6 ITEM C10 44650 38 POWER CABLE SPRA COUPE 7000 CABLE B ...
Page 40: ...38 5 7 ITEM C11 44658 15 JAM VALVE CABLE SPRA COUPE 7000 ...
Page 41: ...39 NOTES ...
Page 42: ...40 NOTES ...