3. Volume

This control allows you to increase or decrease the device's 

volume based on your preference and environmental 

conditions.

Volume setting consists of 6 levels and it is set to 3 by default. 

When you turn off and on the device, it will start with the last 

volume level you chose.

This setting is common to all modes; changes will 

take effect in all modes. 

Adjusting the Volume

1. Press the Power & Settings Button once. Select volume using 

the left and right buttons. The current value will be displayed on 

screen.

2. Change the volume level using the plus (+) and minus (-) buttons.
3. Press the Power & Settings Button once to go back to the main 

screen.
Because the volume level affects power consumption, we 

recommend you not to increase it more than necessary. 

IMPORTANT!

 When you change the volume of the device with 

this setting, the volume of the metal zones adjusted by the 

Tone Volume setting will also change proportionally. 

You can connect wired headphones to the device with the 

headphones adapter cable sold separately. The volume for 

the headphones is also adjusted through the volume setting 

of the device.
When wired headphones are attached, headphones icon will 

appear in the info section at the top of the screen.

4. Tone Settings

These advanced tone settings offer various options to 

modify the sounds The LEGEND generates for targets.

The tone setting offers 6 sub settings as follows: Number of 

Tones , Tone Volume, Tone Frequency, Tone Break, Threshold Level, 

Threshold Frequency. 
Press the Power & Settings Button once. Select the tone setting 

using the left and right buttons. 

When tone is selected, you can see all the tone settings in the second 

row over the settings. To the left of these settings, you will also see 

the icons of buttons to guide you while adjusting these settings.
When the Number of Tones  is 1, there is no tone break point, so 

the Tone Break setting will not be selectable in the menu. 

In the Goldfield mode, the Number of Tones  is 1 and cannot be 

changed. In addition, the Tone Frequency is also not adjustable 

in this mode. Therefore, these 2 settings will not be active in the 

tone settings menu when the Goldfield mode is selected.

To go into the tone settings menu, press the plus (+) button once. 

The selected setting will be shown framed. Using the right and left 

buttons, you can navigate between the settings. You can go back to 

the settings by pressing the Pinpoint & Accept/Reject Button once. 

IMPORTANT!

 To go back to the main screen directly from the 

tone settings menu, press the Power & Settings Button once.

Press

once

16

Park

Goldfield

Beach

Field

Summary of Contents for The LEGEND

Page 1: ......

Page 2: ...nly be disassembled and repaired by Nokta Makro Authorized Service Centers Unauthorized disassembly intrusion into the metal detector control housing for any reason voids the warranty IMPORTANT Do not...

Page 3: ...le on the shaft without stretching too much Then plug the connector to the search coil input socket on the system box and secure by tightening the nut While tightening you may hear clicks indicating t...

Page 4: ...ou navigate between the discrimination patterns offered by The LEGEND 6 Right and Left Buttons On the main screen they are used to navigate between the modes and in the settings menu they are used to...

Page 5: ...r 2 Clock and Time Tracking 3 Search Modes 4 Target ID Scale and Notched Out IDs 5 Operating Frequency 6 Sensitivity Indicator 7 Target ID 8 Depth Indicator 9 User Profile Save Delete 10 FerroCheck Ba...

Page 6: ...unk or glove compartment Do not charge the battery in temperatures over 35 C 95 F or below 0 C 32 F The LEGEND battery can only be replaced by Nokta Makro Detectors or its authorized service centers T...

Page 7: ...in an upright position your arm is relaxed and the search coil is approximately 5cm 2 above the ground Wrong search coil angle Wrong search coil angle Correct search coil angle It is important to keep...

Page 8: ...lower the sensitivity setting 5 You can start detecting Certain settings are common to all modes changes in these settings will take effect in all modes Most of the settings are mode based and they on...

Page 9: ...equency and single frequencies cannot be selected In this mode only the Multi frequency has 2 options Wet sand underwater MW or dry sand with very low salinity WD Each time you press the Frequency But...

Page 10: ...umerically over the indicator The indicator consists of 5 levels Each level represents 6 units of sensitivity The sensitivity values corresponding to each level on the Depth Indicator are shown below...

Page 11: ...r the advantage of covering a broader range of targets on all types of terrains Multi frequency compared to single frequencies typically provides more accurate IDs at depth In addition it offers maxim...

Page 12: ...n the display and ranges between 01 60 The LEGEND s Target ID scale consists of 60 lines each of which represents 1 Target ID In addition to showing the Target ID in the middle of the screen the ID is...

Page 13: ...t buttons Each time you press the button the Target ID will change on screen Select the ID you want to turn off reject or on accept 2 Press the Pinpoint Accept Reject Button If the ID you selected was...

Page 14: ...are required to the automatic balance 1 Find a clear spot without metals 2 Push the Ground Balance Button once and release it The ground balance icon will appear in the info section at the top and the...

Page 15: ...ove the search coil over the target or the target over the search coil in order for the device to detect the target The pinpoint mode is a non motion mode The device continues to give a signal when th...

Page 16: ...a non ferrous ID However it has both ferrous and non ferrous signal IMPORTANT For the FerroCheck feature to work the detector must receive a strong signal Therefore FerroCheck is designed to work with...

Page 17: ...equency is 7 for all frequencies Frequency Shift only affects the mode currently selected changes made in one mode do not affect the others If too much noise is received when the search coil is lifted...

Page 18: ...o section at the top of the screen 4 Tone Settings These advanced tone settings offer various options to modify the sounds The LEGEND generates for targets The tone setting offers 6 sub settings as fo...

Page 19: ...tone volume and tone frequency for all targets 2 Tone The Target ID scale is divided into 2 zones as ferrous and non ferrous The default point that separates these 2 zones vary based on the selected...

Page 20: ...shown framed PARK FIELD BEACH GOLDFIELD Search Mode 1 Tone Z 1 10 10 10 10 Z 2 10 10 10 Z 2 10 10 10 Z 3 10 10 10 Z 4 10 10 10 Z 1 2 1 1 Z 1 2 1 1 Z 2 10 10 10 Z 3 10 10 10 Z 4 10 10 10 Z 5 10 10 10 Z...

Page 21: ...the left of the ID scale the selected zone will be displayed numerically 4 3 Tone Frequency Target IDs for the selected zone Selected target zone Tone Frequency Level for the selected zone 1 30 Low T...

Page 22: ...ft Press the plus button once 3 Using the left and right buttons select the Tone Break setting The selected setting will be shown framed 4 Press the plus button to go into the setting 5 The Tone Break...

Page 23: ...ss the Pinpoint Accept Reject Button once To go back to the main screen press the Power Settings Button once Threshold Tone for Rejected Targets In Park Field and Beach modes The Threshold tone will b...

Page 24: ...the Power Settings Button once Default Threshold Frequencies 4 6 Threshold Frequency PARK FIELD BEACH GOLDFIELD 5 5 5 13 Threshold Frequency Search Mode 1 30 Low Threshold Frequency High Threshold Fr...

Page 25: ...gs IMPORTANT Once you save a user profile if you use that profile as the active user profile all changes you make will be saved automatically To keep your saved settings you must choose another user p...

Page 26: ...ibration icon will be displayed in the info section at the top of the screen 6 Backlight 7 Vibration Park Goldfield Beach Field Park Goldfield Beach Field It enables you to adjust the display backligh...

Page 27: ...d minus buttons 3 When the wireless connection is turned on the Bluetooth Head phones icon will start blinking in the info section at the top of the screen Once it pairs with any Bluetooth headphones...

Page 28: ...on screen when this setting is selected When Time Tracking is selected in the settings the user can see how much time he she has spent with The LEGEND in year month day hour format Displaying the Usa...

Page 29: ...djustable Threshold Yes Notch Filter Yes Ground Balance Automatic Manual Tracking Pinpoint Yes Frequency Shift Yes Noise Cancellation Yes Vibration Yes Sensitivity Setting 30 levels Target ID 01 60 Se...

Page 30: ......