![Nilfisk-Advance Adgressor BR 1050CS Service Manual Download Page 67](http://html.mh-extra.com/html/nilfisk-advance/adgressor-br-1050cs/adgressor-br-1050cs_service-manual_1693177067.webp)
FORM NO. 56043097 / Adgressor
™
/ BR 850S, 850CS, 950S, 950CS, 1050S, 1050CS - 65
ELECTRICAL SYSTEM
Selection of Scrub Switch Operation and Scrub Pressure Limits:
FACTORY DEFAULT: MODE = 3 (PRESSURE INCREASE/DECREASE MODE), LIMIT = 3 (MAXIMUM)
The scrub system switches on the Adgressor/BR 850S and 850CS can be programmed to operate a number of different ways. The operation of the
scrub mode switches is described in the user manual. Following is a description of how to program the control for each mode of operation:
Operation mode 0: Two fi xed pressure settings.
Operation mode 1: Adjustable pressure, increase/decrease mode, nine pressure settings (Advenger mode).
Operation mode 2: Adjustable pressure, light/heavy pressure modes, nine pressure settings.
Operation mode 3: Adjustable pressure, increase/decrease mode, three pressure settings, full pressure range.
Operation mode 4: Adjustable pressure, increase/decrease mode, three pressure settings, low pressure range.
Operation mode 5: Adjustable pressure, increase/decrease mode, three pressure settings, high pressure range.
See the chart below for the equivalent pressure settings for modes 3, 4, and 5.
Adgressor Pressure Settings
Equivalent Pressure Settings (1-9)
Displayed Pressure
Program Option 3
Program Option 4
Program Option 5
Setting
(Full Range)
(Light Range)
(Heavy Range)
1
2
1
3
2
5
4
6
3
9
7
9
NOTE: There are three control panel switches associated with the scrub system. The left-most switch is the scrub system off switch. The center
switch is mainly referred to as the scrub pressure decrease switch. Depending on the scrub switch operating mode, this switch may also be referred
to as the light scrub pressure select switch. The right-most switch is mainly referred to as the scrub pressure increase switch. Depending on the
scrub switch operating mode, this switch may also be referred to as the heavy scrub pressure select switch.
Pressure Increase / Decrease Mode with 3 Pressure Settings (Factory Default)
1 Turn
the
main power key switch to the off position.
2 Press and hold the scrub pressure decrease switch.
3 While holding the pressure decrease switch turn the main power key switch to the on position.
4 Continue to hold the pressure decrease switch until the scrub pressure decrease indicator is green.
5 Release the pressure decrease switch.
6 Pressing and releasing the scrub pressure decrease switch will now select between 0, 1, 2, 3, 4, or 5. Set the mode to 3, 4, or 5 depending
on the range of pressure desired (see above).
7 Press
the
scrub system off switch to save this setting.
8 The status display will now show “d” to indicate that the procedure is done.
9 The new setting will be saved and will remain in effect until it is changed again.
Pressure Increase / Decrease Mode with 9 Pressure Settings (Advenger Mode)
1 Turn
the
main power key switch to the off position.
2 Press and hold the scrub pressure decrease switch.
3 While holding the pressure decrease switch turn the main power key switch to the on position.
4 Continue to hold the pressure decrease switch until the scrub pressure decrease indicator is green.
5 Release the pressure decrease switch.
6 Pressing and releasing the scrub pressure decrease switch will now select between 0, 1, 2, 3, 4, or 5. Set the mode to 1.
7 Press
the
scrub system off switch to save this setting.
8 The status display will now show a number from 1 to 3. This represents the maximum scrub pressure that the operator will be able to select.
Use the pressure decrease switch to set the desired pressure limit.
9 Press
the
scrub system off switch to save this setting.
10 The status display will now show “d” to indicate that the procedure is done.
11 The new setting will be saved and will remain in effect until it is changed again.
SPECIAL PROGRAM OPTIONS (CONTINUED)