FORM NO. 56043097 / Adgressor
™
/ BR 850S, 850CS, 950S, 950CS, 1050S, 1050CS - 41
SOLUTION SYSTEM
FRONT
L
SOLENOID VALVE DISASSEMBLY AND CLEANING
1 Remove the solenoid valve. See the Solenoid Valve Removal section for instructions.
2 See Figure 3. Remove the (4) (I) Screws and disassemble the valve (be careful not to lose any internal parts).
3 Thoroughly wash dirt from block (J) and diaphragm (K).
4 After reassembling, test the solenoid valve for proper operation.
DISC MACHINE SOLUTION PLUMBING DETAIL
•
Top of Hose (L) uses a .109” diameter hole in the center. This prevents unbalanced solution fl ow.
FIGURE 3
FIGURE 4