64 - FORM NO. 56043097 / Adgressor
™
/ BR 850S, 850CS, 950S, 950CS, 1050S, 1050CS
ELECTRICAL SYSTEM
MAIN CONTROL BOARD SPECIAL PROGRAM OPTIONS
Displaying the Control Unit Revision Level:
If it is desired to view the revision level of the control unit perform the following steps:
1 Turn the main power key switch to the off position.
2 Press and hold the scrub system off switch and the speed select switch.
3 While holding both switches turn the main power key switch to the on position.
4 Continue to hold both switches until the speed select indicator is fl ashing.
5 Release both switches.
6 The status display will now indicate the revision level of the control unit. The displayed value will be a letter from A to Z.
7 To exit this mode, turn the main power key switch to the off position.
Selection of Low Voltage Cutout Threshold:
FACTORY DEFAULT: S (STANDARD)
The Adgressor – BR 850S and BR 850CS are equipped with a low voltage cutout feature to prevent over-discharging the batteries. This feature
will automatically shut down the scrub system when the battery voltage falls to the selected threshold. The cutout level is adjustable. The standard
setting is 31 volts (1.72 volts per cell) and the alternate setting is 32.5 volts (1.81 volts per cell). Select the proper cutout level based on the battery
manufacturer’s specifi cations. It is important to note that some maintenance free batteries (including some gelled electrolyte cells) are capable of
being safely discharged down to 1.72 volts per cell. To select between the two cutout levels:
1 Turn the main power key switch to the off position.
2 Press and hold the scrub system off switch.
3 While holding the scrub system off switch turn the main power key switch to the on position.
4 Continue to hold the scrub system off switch until the scrub off indicator turns green.
5 Release the scrub off switch.
6 The status display will now show “S” or “A”. Pressing and releasing the scrub off switch will now select between the two options. For the
standard cutout level, select “S”. For the alternate cutout level, select “A”.
7 To save the new setting, turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.