![NIKKARI SSBC Instruction Manual Download Page 20](http://html1.mh-extra.com/html/nikkari/ssbc/ssbc_instruction-manual_1689295020.webp)
20
3.1.3 Removing
Loosen the knob bolt [1] of powerhead
connections.
Lift the positioning knob [5], and turn
it.
When the positioning knob is lifted,
it can be rotated both clockwise and
counterclockwise by 90°
.
Pull out the shaft tube [6].
If the shaft tube is hard to remove, hold
it so that the attachment is parallel to
the pipe of the powerhead, and then
pull out it.
Turn the positioning knob [5] until it
comes to the center.
When the positioning knob is returned
to the center, it will be released
downward.
[1]
1
[5]
2
[5]
[6]
3
4