60
SI-INTERBUS User Guide
Issue Number: 1
10
SI-Applications parameters
The SI-Interbus will redirect any menu accesses, for menus 70 to 91, to the
SI-Applications (or MCi2x0) module in the lowest numbered slot. This is convenient to
use if there is only the one SI-Applications (or MCi2x0) module fitted to the drive, as it
guarantees that data will always be written to or read from the module even if it was
moved to a different slot position.
If more than one SI-Applications (or MCi2x0) option module is fitted then, to ensure the
correct module is accessed, it will be necessary to access the module in a specific slot
directly, this is achieved by using the slot specific menus 100 to 121, 130 to 151 and
160 to 181 for menus 70 to 91 in slots 1 to 3 respectively.
Note that only the PLC registers (menus 70 to 79) are available in the MCi2x0 module.
Table 10-1 Applications parameters
10.1
Single SI-Applications fitted
Consider a drive with the following configuration:
•
Slot 1 - Vacant
•
Slot 2 - SI-Interbus
•
Slot 3 - SI-Applications
If a parameter read request comes over Interbus to read Pr
71.08
, this will be redirected
to the SI-Applications in the lowest slot number, i.e. the SI-Applications in slot 3.
The value in _Q08% from slot 3 will be returned.
If a parameter read request comes over Interbus to read Pr
161.08
, this will be sent
straight to the SI-Applications in slot 3. The value in _Q08% from slot 3 will be returned.
If a parameter read request comes over Interbus to read Pr
101.08
, this will be sent
straight to slot 1. As there is no module fitted in slot 1, an error message will be
returned, indicating that the parameter does not exist.
SI-Applications Parameters
SI-Apps
Compact
MCi2x0
Parameter
Reference
Direct to
slot 1
Direct to
slot 2
Direct to
slot 3
_Pxx% PLC registers
Yes
Yes
Pr
70.xx
Pr
100.xx
Pr
130.xx
Pr
160.xx
_Qxx% PLC Registers
Yes
Yes
Pr
71.xx
Pr
101.xx
Pr
131.xx
Pr
161.xx
_Rxx% PLC Registers
Yes
Yes
Pr
72.xx
Pr
102.xx
Pr
132.xx
Pr
162.xx
_Sxx% PLC Registers
Yes
Yes
Pr
73.xx
Pr
103.xx
Pr
133.xx
Pr
163.xx
_Txx% PLC Registers
Yes
Yes
Pr
74.xx
Pr
104.xx
Pr
134.xx
Pr
164.xx
_Uxx% PLC Registers
Yes
Yes
Pr
75.xx
Pr
105.xx
Pr
135.xx
Pr
165.xx
_Vxx% PLC Registers
Yes
Yes
Pr
76.xx
Pr
106.xx
Pr
136.xx
Pr
166.xx
_Wxx% PLC Registers
Yes
Yes
Pr
77.xx
Pr
107.xx
Pr
137.xx
Pr
167.xx
_Xxx% PLC Registers
Yes
Yes
Pr
78.xx
Pr
108.xx
Pr
138.xx
Pr
168.xx
_Yxx% PLC Registers
Yes
Yes
Pr
79.xx
Pr
109.xx
Pr
139.xx
Pr
169.xx
Local Configuration Parameters
Yes
No
Pr
81.xx
Pr
111.xx
Pr
141.xx
Pr
171.xx
Timer Configuration Parameters
Yes
No
Pr
85.xx
Pr
115.xx
Pr
145.xx
Pr
175.xx
Digital IO Parameters
Yes
No
Pr
86.xx
Pr
116.xx
Pr
146.xx
Pr
176.xx
Status Parameters
Yes
No
Pr
88.xx
Pr
118.xx
Pr
148.xx
Pr
178.xx
General Parameters
Yes
No
Pr
90.xx
Pr
120.xx
Pr
150.xx
Pr
180.xx
Fast Access Parameters
Yes
No
Pr
91.xx
Pr
121.xx
Pr
151.xx
Pr
181.xx