2.4) Mounting the motor bracket to the pillar (Fig. 6)

Use screws which are suitable for the material the pillar is made of. Mount the bracket horizontally.

2.5) Assembly of the straight arm (Fig. 7)

Use the M8x25 screw with its relative grower washer. Make sure the arm is positioned by making it come out of the front part.

2.6) Mounting the gearmotor (Fig. 8)

Insert the POP in the plate at point C and mount it onto the former using M6x100 screws and the nuts supplied.

Use the M8x45 screw complete with plastic washer to mount the

two arms, and the M8x35 screw for mounting the curved arm with

the adjustable bracket.

The bracket is either welded to the gate or fastened to it using screws

which are suitable for the material the leaf is made of. The two brack-

ets must be 500mm apart (

Fig. 5-6

), fastened horizontally, and off-

set compared with the motor bracket at 100mm.

2.8) Releasing the gearmotor from the inside (Fig. 10)

This is carried out in two steps: 

A

: lift the cover.

B

: insert the release key supplied and turn it clockwise until it stops.

The release system is assembled in six steps: 

A

: remove the plastic cover (1)

B

: screw the pin (3) onto the release shaft (2) 

C

: screw the cable stretcher (4) into the special hole (5)

D

: secure the spring (6) to the pin (3) and to the fastening point visi-

ble in the shell.

E

: slide the release cable (7) into the pin hole (3) and cable stretcher (4).

F

: replace the plastic cover (1) to its original position.

2.8.1) Releasing the gearmotor from the outside (Fig. 11) (optional)

2.9) Securing the opening stop (Fig. 12)

This is carried out after unblocking the gearmotor, using two M6x25 screws placed in the most suitable position.

2.10) Electrical connections

Consult the Control Unit POA1 instruction booklet for the electrical connections. 

2.11) Connection to the power supply (Fig. 13)

On PP7024

: connect the 230V supply cable directly to the fuse holder terminal.

On PP7224

: connect the cable from the PP7024 unit to the mammoth terminal.

2.12) Using buffer batteries (Fig. 14) (optional)

POP comes complete with housing for buffer batteries (optional). Break open the plastic cap on the control unit box in order to connect the

box with the battery.

The manual operation (

Fig. 10

) must be resorted to in case of pow-

er failures or system malfunctions.

The manual manoeuvre only allows the gearmotor to travel freely if it

is assembled correctly, complete with original accessories.

3) Manual or release manoeuvre 

2.7) Assembling the curved arm and mounting the adjustable bracket to the leaf (Fig. 9)

Summary of Contents for Pop PP7024

Page 1: ...vvertenze per l installatore Instructions and warnings for the fitter Instructions et recommandations pour l installation Anweisungen und hinweise f r den installateur Instrucciones j advertencias par...

Page 2: ...1 2 3...

Page 3: ...5 6 7 4 5 4 3 3 6 7 1 2 7 8...

Page 4: ...8 9 10 A B 11 4 1 6 7 5 2 3 12...

Page 5: ...or other open devices In the event that liquid substances have penetrated inside the automa tion devices immediately disconnect the power supply and contact the NICE customer service department The u...

Page 6: ...he mounting surfaces of the photocells are flat and that they enable the proper alignment between TX and RX Check that there is enough space for the arm to rotate Fig 3 2 2 Typical system Fig 4 1 POP...

Page 7: ...elease shaft 2 C screw the cable stretcher 4 into the special hole 5 D secure the spring 6 to the pin 3 and to the fastening point visi ble in the shell E slide the release cable 7 into the pin hole 3...

Page 8: ...tances do not pollute the environment Enquire about the recycling or disposal systems available in compliance with regulations locally in force 1 Disconnect the automation system from the electric mai...

Page 9: ...ents a system that is safe reliable long lasting and built in accordance with the regulations in force An automation system is not only very convenient it also improves the level of security in your h...

Page 10: ...has performed them these documents must remain under the custody of the owner of the system Disposal At the end of its useful life the automation must be dis mantled by qualified personnel and the mat...

Page 11: ...le e di altri dispositivi aperti Qualora sostanze liquide siano penetrate all interno dei dispositivi del l automatismo scollegare immediatamente l alimentazione elettrica e rivolgersi al servizio di...

Page 12: ...corretto allineamento tra TX e RX Verificare che vi sia uno spazio sufficiente alla rotazione del brac cio Fig 3 2 2 Impianto tipico Fig 4 1 Attuatore POP PP7024 2 Attuatore POP PP7224 3 Fotocellula...

Page 13: ...Il montaggio del sistema di sblocco viene eseguito in sei fasi A Staccare il coperchietto in plastica 1 B Avvitare sull albero di sblocco 2 il pernetto 3 C Avvitare il tendicorda 4 nell apposito foro...

Page 14: ...ormatevi sui sistemi di riciclaggio o smaltimento attenendovi alle norme in vigore a livello locale 1 Staccare l automatismo dalla rete elettrica 2 Smontare tutti i dispositivi ed accessori seguendo i...

Page 15: ...esigenze sicuro ed affidabile nel tempo e soprattutto a regola d arte rispondente cio alle normative in vigore Un impianto di automazione una bella comodit oltre che un valido sistema di sicurezza e...

Page 16: ...di regolazione dell automazione la respon sabilit del vostro installatore Il collaudo finale le manutenzioni periodiche e le eventuali riparazioni devono essere documentate da chi le esegue e i docum...

Page 17: ...installation galement viter que des liquides puissent p n trer l int rieur de la logique de commande et d autres dispositifs ouverts Si des substances liquides ont p n tr l int rieur des dispositifs d...

Page 18: ...de fixation des photocellules sont plates et permet tent un alignement correct entre TX et RX Il y a un espace suffisant pour la rotation du bras Fig 3 2 2 Installation typique Fig 4 1 Op rateur POP P...

Page 19: ...tu en six phases A D tacher le couvercle en plastique 1 B Visser le petit pivot 3 sur l arbre de d brayage 2 C Visser le tendeur de c ble 4 dans le trou 5 pr vu cet effet D Fixer le ressort 6 au pivot...

Page 20: ...er dans la nature Informez vous sur les sys t mes de recyclage ou de mise au rebut en respectant les normes locales en vigueur 1 D brancher l automatisme du secteur lectrique 2 D monter tous les dispo...

Page 21: ...ut e dans les r gles de l art et conforme par cons quent aux normes en vigueur Une installation d automatisation est une belle commodit ainsi qu un sys t me de s curit valable avec quelques attentions...

Page 22: ...stallateur L essai de fonctionnement final les maintenances p riodiques et les ventuelles r parations doivent tre document s par la personne qui s en charge et les documents doivent tre conserv s par...

Page 23: ...13 14 PP7024 PP7224...

Page 24: ...15...

Page 25: ...wer operated doors Test methods EN 12453 8 2000 Porte e cancelli industriali e commerciali e da autorimessa Sicurezza in uso di porte motorizzate Requisiti Industrial commercial and garage doors and g...

Reviews: