Sound pressure levels
F2040 is usually placed next to a house wall, which gives
a directed sound distribution that should be considered.
Accordingly, you should always attempt when position-
ing to choose the side that faces the least sound sensitive
neighbouring area.
The sound pressure levels are further affected by walls,
bricks, differences in ground level, etc and should
therefore only be seen as guide values.
F2040 adjusts the fan speed depending on the ambient
temperature and evaporation temperature.
2 m
6 m
10 m
2 m
LEK
F2040-16
F2040-12
F2040-8
F2040-6
Air/water heat pump
61
57
54
50
L
W
(A)
Sound power level* According to EN12102 at 7/45 (nominal)
47
43
40
36
dB(A)
Sound pressure level at 2 m free standing.*
37.5
33.5
30.5
26.5
dB(A)
Sound pressure level at 6 m free standing.*
33
29
26
22
dB(A)
Sound pressure level at 10 m free standing.*
* Free space.